Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Feb;21(2):238-43.
doi: 10.1007/s11695-010-0308-7.

Smaller staple height for circular stapled gastrojejunostomy in laparoscopic gastric bypass: early results in 1,074 morbidly obese patients

Affiliations

Smaller staple height for circular stapled gastrojejunostomy in laparoscopic gastric bypass: early results in 1,074 morbidly obese patients

Nasser Sakran et al. Obes Surg. 2011 Feb.

Abstract

Background: Anastomotic leaks, stenosis, and bleeding from the gastrojejunal anastomosis (GJA) after gastric bypass may carry high morbidity and mortality. To date, the standard operation with the circular stapler (CS) used the 25 mm with a staple height of 4.8 mm. We present herein our experience with the 3.5-mm staple height.

Methods: A total of 1,074 morbidly obese patients who underwent fully stapled laparoscopic Roux-en-Y Gastric Bypass over a period of 18 months were included in the study. Mean body mass index was 41.9 (range 28.6-70.7). Mean age was 40.9 years (range 15-74 years). Mean operating time was 73 min (range 43-210 min) and the mean length of stay was 4.2 days (range 1-25 days). The 30-day complication rate associated with GJA was prospectively analyzed.

Results: Twenty patients (1.86%) developed postoperative bleeding. Four developed GJA bleeding (0.37%). One leak was recorded from the vertical staple line of the gastric pouch, but no leaks from the GJA were seen. Conversion to open approach was required in two patients (0.18%). Reoperation and readmission rates were 1.7% and 1.8%, respectively. Perioperative complications were observed in 34 patients (3.1%). One case of clinical GJA stenosis was detected in a mean follow-up of 10.5 months (range 5-20 months). There was no mortality in our series.

Conclusion: Compared to our previous experience with 4.8 mm CS, creating the GJA using a smaller staple height significantly reduced the bleeding rate and seems to be a safe technique that potentially reduces other complications related to the GJA as reported in the literature.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Obes Surg. 2000 Dec;10(6):540-2 - PubMed
    1. Obes Surg. 2003 Feb;13(1):62-5 - PubMed
    1. Curr Probl Surg. 1998 Sep;35(9):791-858 - PubMed
    1. Arch Surg. 2003 May;138(5):520-3; discussion 523-4 - PubMed
    1. J Am Coll Surg. 2004 Oct;199(4):543-51 - PubMed

LinkOut - more resources