Critical comparison of MS and immunoassays for the bioanalysis of therapeutic antibodies
- PMID: 21083085
- DOI: 10.4155/bio.09.121
Critical comparison of MS and immunoassays for the bioanalysis of therapeutic antibodies
Abstract
Therapeutic antibody assessment in biofluids requires fit-for-purpose bioanalytical methods. The reference is the immunoassay, the accuracy of which may be compromised by interference by endogenous components. Here, we report the inherent analytical problems posed by immunoassays and propose an alternative based on LC-MS that should be readily applicable to the analysis of therapeutic antibodies in biological fluids. We review problems linked to assay sensitivity, the choice of the assay format involving either immunodetection or MS, and strategies in the assessment of bound versus free forms.
Similar articles
-
Bioanalysis of recombinant proteins and antibodies by mass spectrometry.Analyst. 2009 May;134(5):825-34. doi: 10.1039/b819706g. Epub 2009 Mar 24. Analyst. 2009. PMID: 19381370 Review.
-
Bioanalytical methods for the quantification of therapeutic monoclonal antibodies and their application in clinical pharmacokinetic studies.Hum Antibodies. 2009;18(3):47-73. doi: 10.3233/HAB-2009-0206. Hum Antibodies. 2009. PMID: 19729801 Review.
-
Measurement of urinary free cortisol by tandem mass spectrometry and comparison with results obtained by gas chromatography-mass spectrometry and two commercial immunoassays.Ann Clin Biochem. 2008 Jul;45(Pt 4):380-8. doi: 10.1258/acb.2007.007119. Ann Clin Biochem. 2008. PMID: 18583623
-
Bioanalytical LC-MS of therapeutic oligonucleotides.Bioanalysis. 2011 Mar;3(5):541-64. doi: 10.4155/bio.11.8. Bioanalysis. 2011. PMID: 21388267 Review.
-
Enhanced resolution triple-quadrupole mass spectrometry for fast quantitative bioanalysis using liquid chromatography/tandem mass spectrometry: investigations of parameters that affect ruggedness.Rapid Commun Mass Spectrom. 2003;17(1):24-38. doi: 10.1002/rcm.872. Rapid Commun Mass Spectrom. 2003. PMID: 12478552
Cited by
-
Glycome characterization of immunoglobulin G from buffalo (Bubalus bubalis) colostrum.Glycoconj J. 2015 Nov;32(8):625-34. doi: 10.1007/s10719-015-9608-4. Epub 2015 Aug 4. Glycoconj J. 2015. PMID: 26239923
-
Analysis of Pembrolizumab in Human Plasma by LC-MS/HRMS. Method Validation and Comparison with Elisa.Biomedicines. 2021 May 30;9(6):621. doi: 10.3390/biomedicines9060621. Biomedicines. 2021. PMID: 34070939 Free PMC article.
-
Multiplex Hybrid Antigen-Capture LC-MRM Quantification in Sera and Nasal Lining Fluid of AZD7442, a SARS-CoV-2-Targeting Antibody Combination.Anal Chem. 2022 Nov 1;94(43):14835-14845. doi: 10.1021/acs.analchem.2c01320. Epub 2022 Oct 21. Anal Chem. 2022. PMID: 36269894 Free PMC article.
-
Nano-scale liquid chromatography/mass spectrometry and on-the-fly orthogonal array optimization for quantification of therapeutic monoclonal antibodies and the application in preclinical analysis.J Chromatogr A. 2012 Aug 17;1251:63-73. doi: 10.1016/j.chroma.2012.06.007. Epub 2012 Jun 21. J Chromatogr A. 2012. PMID: 22770385 Free PMC article.
-
Toward sensitive and accurate analysis of antibody biotherapeutics by liquid chromatography coupled with mass spectrometry.Drug Metab Dispos. 2014 Nov;42(11):1858-66. doi: 10.1124/dmd.114.058917. Epub 2014 Sep 2. Drug Metab Dispos. 2014. PMID: 25185260 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources