Restricted-access media supports for direct high-throughput analysis of biological fluid samples: review of recent applications
- PMID: 21083154
- DOI: 10.4155/bio.09.39
Restricted-access media supports for direct high-throughput analysis of biological fluid samples: review of recent applications
Abstract
This review presents an update on the use of restricted-access materials (RAMs) for direct injection of biological samples. The fundamental improvements in the preparation of tailored RAMs and the diversity of applications with these phases are presented. Insights into diminishing the matrix effect by the use of RAM supports in methods by LC-MS and into the low number of methods for enantiomeric separations by direct injections of biological samples are addressed. The diversity of systems that incorporate RAMs for selective sample clean-up or fractionation in proteome and peptidome analysis is also covered.
Similar articles
-
Capillary column switching restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry system for simultaneous and direct analysis of drugs in biofluids.Anal Chem. 2007 Aug 15;79(16):6359-67. doi: 10.1021/ac070671g. Epub 2007 Jul 12. Anal Chem. 2007. PMID: 17628079
-
Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.J Biochem Biophys Methods. 2007 Mar 10;70(2):263-73. doi: 10.1016/j.jbbm.2006.10.001. Epub 2006 Oct 10. J Biochem Biophys Methods. 2007. PMID: 17113152 Review.
-
A method for the direct analysis of drug compounds in plasma using a single restricted access material (RAM) column.J Pharm Biomed Anal. 2004 Nov 15;36(3):457-64. doi: 10.1016/j.jpba.2004.07.029. J Pharm Biomed Anal. 2004. PMID: 15522518
-
Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.J Pharm Biomed Anal. 2007 Jun 28;44(2):342-55. doi: 10.1016/j.jpba.2007.02.006. Epub 2007 Feb 13. J Pharm Biomed Anal. 2007. PMID: 17360141 Review.
-
The use of partially porous particle columns for the routine, generic analysis of biological samples for pharmacokinetic studies in drug discovery by reversed-phase ultra-high performance liquid chromatography-tandem mass spectrometry.J Pharm Biomed Anal. 2009 Jan 15;49(1):100-7. doi: 10.1016/j.jpba.2008.09.041. Epub 2008 Oct 4. J Pharm Biomed Anal. 2009. PMID: 19019615
Cited by
-
Polycaprolactone Composite Micro/Nanofibrous Material as an Alternative to Restricted Access Media for Direct Extraction and Separation of Non-Steroidal Anti-Inflammatory Drugs from Human Serum Using Column-Switching Chromatography.Nanomaterials (Basel). 2021 Oct 12;11(10):2669. doi: 10.3390/nano11102669. Nanomaterials (Basel). 2021. PMID: 34685117 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical