Multidimensional approaches in LC and MS for phospholipid bioanalysis
- PMID: 21083211
- DOI: 10.4155/bio.10.52
Multidimensional approaches in LC and MS for phospholipid bioanalysis
Abstract
The advancement of both LC and MS has contributed significantly to phospholipid analysis. Two major trends of developments have emerged in the past decade: application of dedicated online (or offline) LC-MS techniques including 2D and sophisticated chromatographic separations, and the development of so-called shotgun lipidomics represented by multidimensional MS-based techniques. However, neither of these techniques have been shown to be a universal solution for the increasing demand on the comprehensive information of lipid metabolomics in lipidomics studies. This is partially due to the intrinsic complexity of naturally occurring phospholipids in practice. It is evident that either chromatography or MS has to go multidimensional in order to fulfil this goal. This review focuses on recent developments of multidimensional MS, LC-MS and chromatographic approaches for lipidomics analysis. The perspectives and retrospectives of chromatography and MS in these aspects will be reviewed and discussed.
Similar articles
-
A shotgun tandem mass spectrometric analysis of phospholipids with normal-phase and/or reverse-phase liquid chromatography/electrospray ionization mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(5):654-66. doi: 10.1002/rcm.1836. Rapid Commun Mass Spectrom. 2005. PMID: 15700236
-
Application of LC-MS for quantitative analysis and metabolite identification of therapeutic oligonucleotides.J Pharm Biomed Anal. 2007 Jun 28;44(2):330-41. doi: 10.1016/j.jpba.2007.01.042. Epub 2007 Feb 2. J Pharm Biomed Anal. 2007. PMID: 17339091 Review.
-
Electrospray ionization tandem mass spectrometry (ESI-MS/MS)-based shotgun lipidomics.Methods Mol Biol. 2011;708:259-75. doi: 10.1007/978-1-61737-985-7_16. Methods Mol Biol. 2011. PMID: 21207296
-
High-throughput quantitative bioanalysis by LC/MS/MS.Biomed Chromatogr. 2000 Oct;14(6):422-9. doi: 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO;2-I. Biomed Chromatogr. 2000. PMID: 11002279 Review.
-
Multidimensional chromatography coupled to mass spectrometry in analysing complex proteomics samples.J Sep Sci. 2010 Jun;33(10):1421-37. doi: 10.1002/jssc.201000050. J Sep Sci. 2010. PMID: 20486207 Review.
Cited by
-
Applications of Fourier Transform Ion Cyclotron Resonance (FT-ICR) and Orbitrap Based High Resolution Mass Spectrometry in Metabolomics and Lipidomics.Int J Mol Sci. 2016 May 25;17(6):816. doi: 10.3390/ijms17060816. Int J Mol Sci. 2016. PMID: 27231903 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous