Performance properties of filter paper devices for whole blood collection
- PMID: 21083340
- DOI: 10.4155/bio.10.73
Performance properties of filter paper devices for whole blood collection
Abstract
Background: The Newborn Screening Quality Assurance Program at the Centers for Disease Control and Prevention assesses the adherence to established performance standards of manufactured lots of whole blood filter paper collection devices that are registered by the US FDA. We examined 26 newborn screening analytes measured from blood applied to filter papers from two FDA-cleared sources, Whatman(®) Grade 903 and Ahlstrom Grade 226. The dried blood spots contained analytes at both single levels and dose-response series.
Results: We observed overlap at one standard deviation for each analyte, with no more than 4-5% difference between the papers.
Conclusion: The data demonstrated similarities of analyte recovery between the papers, indicating comparability of the devices for newborn screening and other applications.
Similar articles
-
Use of filter paper discs as substrate for collection and storage of blood samples for screening of anti-tetanus toxoid antibodies.Diagn Clin Immunol. 1988;5(5):262-5. Diagn Clin Immunol. 1988. PMID: 3359568
-
[Detection of rubella antibodies in blood samples collected on filter paper].Rev Argent Microbiol. 1997 Apr-Jun;29(2):84-91. Rev Argent Microbiol. 1997. PMID: 9424629 Spanish.
-
Use of filter paper for the collection and analysis of human whole blood specimens.J Nutr. 2001 May;131(5):1631S-6S. doi: 10.1093/jn/131.5.1631S. J Nutr. 2001. PMID: 11340130 Review.
-
A simple method for collecting measured whole blood with quantitative recovery of antibody activities for serological surveys.J Immunol Methods. 2007 Mar 30;320(1-2):164-71. doi: 10.1016/j.jim.2006.12.007. Epub 2007 Jan 16. J Immunol Methods. 2007. PMID: 17270207
-
Dried blood spot sampling in combination with LC-MS/MS for quantitative analysis of small molecules.Biomed Chromatogr. 2010 Jan;24(1):49-65. doi: 10.1002/bmc.1367. Biomed Chromatogr. 2010. PMID: 20017122 Review.
Cited by
-
An overview of the clinical use of filter paper in the diagnosis of tropical diseases.Am J Trop Med Hyg. 2014 Feb;90(2):195-210. doi: 10.4269/ajtmh.13-0463. Epub 2013 Dec 23. Am J Trop Med Hyg. 2014. PMID: 24366501 Free PMC article. Review.
-
Dried urine spot method for detection of Schistosoma mansoni circulating cathodic antigen in resource-limited settings: a proof of concept study.Front Immunol. 2023 Sep 11;14:1216710. doi: 10.3389/fimmu.2023.1216710. eCollection 2023. Front Immunol. 2023. PMID: 37753086 Free PMC article.
-
Dried blood spots--preparing and processing for use in immunoassays and in molecular techniques.J Vis Exp. 2015 Mar 13;(97):52619. doi: 10.3791/52619. J Vis Exp. 2015. PMID: 25867233 Free PMC article.
-
Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications.Mass Spectrom Rev. 2020 Jul;39(4):336-370. doi: 10.1002/mas.21601. Epub 2019 Sep 6. Mass Spectrom Rev. 2020. PMID: 31491055 Free PMC article. Review.
-
Consistency in the Assessment of Dried Blood Spot Specimen Size and Quality in U.K. Newborn Screening Laboratories.Int J Neonatal Screen. 2024 Sep 5;10(3):60. doi: 10.3390/ijns10030060. Int J Neonatal Screen. 2024. PMID: 39311362 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources