Analysis of index modulation in microembolic Doppler signals part I: radiation force as a new hypothesis-simulations
- PMID: 21084152
- DOI: 10.1016/j.ultrasmedbio.2010.09.006
Analysis of index modulation in microembolic Doppler signals part I: radiation force as a new hypothesis-simulations
Abstract
The purpose of this study was to reveal the cause of frequency modulation (FM) present in microembolic Doppler ultrasound signals. This novel explanation should help the development of sensitive microembolus discrimination techniques. We suggest that the frequency modulation detected is caused by the ultrasonic radiation force (URF) acting directly on microemboli. The frequency modulation and the imposed displacement were calculated using a numerical dynamic model. By setting simulation parameters with practical values, it was possible to reproduce most microembolic frequency modulation signatures. The most interesting findings in this study were that: (1) the ultrasound radiation force acting on a gaseous microembolus and its corresponding cumulative displacement were far higher than those obtained for a solid microembolus, and that is encouraging for discrimination purposes; and 2) the calculated frequency modulation indices (FMIs) (≈20 kHz) were in good agreement with literature results. By taking into account the URF, the flow pulsatility, the beam-to-flow angle and both the velocity and the ultrasound beam profiles, it was possible to explain all erratic FM signatures of a microbubble. Finally, by measuring FMI from simulated Doppler signals and by using a constant threshold of 1 KHz, it was possible to discriminate gaseous from solid microemboli with ease.
Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Analysis of index modulation of doppler microembolic signals part II: in vitro discrimination.Ultrasound Med Biol. 2011 Jan;37(1):102-11. doi: 10.1016/j.ultrasmedbio.2010.10.014. Ultrasound Med Biol. 2011. PMID: 21144961
-
[Detection of cerebral microemboli by transcranial doppler. Technical aspects].Neurol Neurochir Pol. 2002 Jul-Aug;36(4):791-9. Neurol Neurochir Pol. 2002. PMID: 12418142 Review. Polish.
-
Microembolus detection by transcranial doppler sonography.Eur J Ultrasound. 2002 Nov;16(1-2):21-30. doi: 10.1016/s0929-8266(02)00046-0. Eur J Ultrasound. 2002. PMID: 12470847 Review.
-
Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.Stroke. 2002 Aug;33(8):1975-80. doi: 10.1161/01.str.0000022809.46400.4b. Stroke. 2002. PMID: 12154248 Clinical Trial.
-
Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.Stroke. 2005 Aug;36(8):1731-4. doi: 10.1161/01.STR.0000173399.20127.b3. Epub 2005 Jul 14. Stroke. 2005. PMID: 16020767
Cited by
-
An in vitro comparison of embolus differentiation techniques for clinically significant macroemboli: dual-frequency technique versus frequency modulation method.Ultrasound Med Biol. 2014 Nov;40(11):2642-54. doi: 10.1016/j.ultrasmedbio.2014.06.003. Epub 2014 Sep 11. Ultrasound Med Biol. 2014. PMID: 25218455 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources