A solution to the problem of high-flow jets from miniature angiographic catheters
- PMID: 2108548
- DOI: 10.2214/ajr.154.5.2108548
A solution to the problem of high-flow jets from miniature angiographic catheters
Abstract
In this study we evaluated methods for reducing high-flow jets from 5-French catheters that occur when injection pressures approach catheter tolerance (1000 psi [6.9 MPa]). This "jet effect" has been responsible for subintimal extravasation of contrast material in patients. We designed a physical model that accurately measures flow rates through the end hole and each side hole of 5-French high-flow catheters under simulated physiologic arterial pressure. When a standard catheter commonly used for injection of contrast material was studied, flow of contrast material was 34% through the end hole and 31% through the distal side-hole pair at high injection pressures (1000 psi). We examined the effect of altering the size and configuration of catheter side holes and end hole in an effort to create an improved flow profile, and thus a safer angiographic catheter. End-hole flow rate was reduced by 73% to 9% of total flow by tapering the 5-French catheter to 0.018 in. (0.046 cm) and by using smaller 0.015-in. (0.038-cm) side holes for even flow distribution. The high-flow jets present with standard high-flow 5-French catheters do not occur when flow-restrictive end holes and side holes are used. A uniform flow profile can be obtained without sacrificing delivery of contrast material through small catheters.
Comment in
-
High-velocity jets from 5-French catheters.AJR Am J Roentgenol. 1991 Apr;156(4):874-5. doi: 10.2214/ajr.156.4.2003465. AJR Am J Roentgenol. 1991. PMID: 2003465 No abstract available.
Similar articles
-
New high-flow "cloud" catheter for safer delivery of contrast material.Radiology. 1989 Nov;173(2):461-4. doi: 10.1148/radiology.173.2.2798879. Radiology. 1989. PMID: 2798879
-
Modifying peripheral IV catheters with side holes and side slits results in favorable changes in fluid dynamic properties during the injection of iodinated contrast material.AJR Am J Roentgenol. 2009 Oct;193(4):970-7. doi: 10.2214/AJR.09.2521. AJR Am J Roentgenol. 2009. PMID: 19770318
-
Comparison of side hole versus non side hole high flow hemodialysis catheters.Hemodial Int. 2006 Jan;10(1):63-7. doi: 10.1111/j.1542-4758.2006.01176.x. Hemodial Int. 2006. PMID: 16441829
-
A new miniature catheter with side-holes for percutaneous transradial or transbrachial coronary angiography.J Invasive Cardiol. 2002 Jul;14(7):379-84. J Invasive Cardiol. 2002. PMID: 12082190
-
A quantitative method for determining angiographic jet energy forces and their dissipation: theoretic and practical implications.Cathet Cardiovasc Diagn. 1977;3(2):139-54. doi: 10.1002/ccd.1810030207. Cathet Cardiovasc Diagn. 1977. PMID: 872208
Cited by
-
More holes, more contrast? Comparing an 18-gauge non-fenestrated catheter with a 22-gauge fenestrated catheter for cardiac CT.PLoS One. 2020 Jun 8;15(6):e0234311. doi: 10.1371/journal.pone.0234311. eCollection 2020. PLoS One. 2020. PMID: 32511272 Free PMC article.
-
Computational analysis of the effectiveness of blood flushing with saline injection from an intravascular diagnostic catheter.Int J Numer Method Biomed Eng. 2014 Nov;30(11):1278-93. doi: 10.1002/cnm.2657. Epub 2014 Jul 17. Int J Numer Method Biomed Eng. 2014. PMID: 24953876 Free PMC article.
-
Catheters in vascular interventional radiology: an illustrated review.Diagn Interv Radiol. 2023 Jan 31;29(1):138-145. doi: 10.5152/dir.2022.21233. Epub 2022 Dec 28. Diagn Interv Radiol. 2023. PMID: 36960563 Free PMC article. Review.
-
Influence of contrast-enhanced ultrasound administration setups on microbubble enhancement: a focus on pediatric applications.Pediatr Radiol. 2018 Jan;48(1):101-108. doi: 10.1007/s00247-017-3976-9. Epub 2017 Sep 11. Pediatr Radiol. 2018. PMID: 28894889
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources