Effect of the simulated periodontal ligament on cast post-and-core removal using an ultrasonic device
- PMID: 21085812
- PMCID: PMC4246387
- DOI: 10.1590/s1678-77572010000500017
Effect of the simulated periodontal ligament on cast post-and-core removal using an ultrasonic device
Abstract
Objective: The aim of this study was to evaluate the effect of simulated periodontal ligament (SPDL) on custom cast dowel and core removal by ultrasonic vibration.
Material and methods: Thirty-two human maxillary canines were included in resin cylinders with or without SPDL made from polyether impression material. In order to allow tensile testing, the roots included in resin cylinders with SPDL were fixed to cylinders with two stainless steel wires. Post-holes were prepared by standardizing the length at 8 mm and root canal impressions were made with self-cured resin acrylic. Cast dowel and core sets were fabricated and luted with Panavia F resin cement. Half of the samples were submitted to ultrasonic vibration before the tensile test. Data were analyzed statistically by two-way ANOVA and Tukey's post-hoc tests (p<0.05).
Results: The ultrasonic vibration reduced the tensile strength of the samples directly included in resin cylinders. There was no difference between the values, whether or not ultrasonic vibration was used, when the PDL was simulated. However, the presence of SPDL affected the tensile strength values even when no ultrasonic vibration was applied.
Conclusion: Simulation of PDL has an effect on both ultrasonic vibration and tensile testing.
Figures




Similar articles
-
Different ultrasonic vibration protocols and their effects on retention of post-and-core to root canal.Gen Dent. 2013 Aug;61(5):40-2. Gen Dent. 2013. PMID: 23928437
-
Comparison of different ultrasonic vibration modes for post removal.Braz Dent J. 2012;23(1):49-53. doi: 10.1590/s0103-64402012000100009. Braz Dent J. 2012. PMID: 22460315
-
Comparison of two luting agents used for the retention of cast dowel and cores.J Prosthodont. 2005 Sep;14(3):164-9. doi: 10.1111/j.1532-849X.2005.00349.x. J Prosthodont. 2005. PMID: 16336233
-
Comparative study of the effect of ultrasound on the removal of intracanal posts.Gen Dent. 2009 Sep-Oct;57(5):492-5. Gen Dent. 2009. PMID: 19903640 Clinical Trial.
-
Influence of luting agents on time required for cast post removal by ultrasound: an in vitro study.J Appl Oral Sci. 2009 May-Jun;17(3):145-9. doi: 10.1590/s1678-77572009000300003. J Appl Oral Sci. 2009. PMID: 19466241 Free PMC article.
Cited by
-
Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts.J Appl Oral Sci. 2014 Sep-Oct;22(5):450-8. doi: 10.1590/1678-775720140067. J Appl Oral Sci. 2014. PMID: 25466478 Free PMC article.
References
-
- Alfredo E, Garrido AD, Souza-Filho CB, Correr-Sobrinho L, Sousa-Neto MD. In vitro evaluation of the effect of core diameter for removing radicular post with ultrasound. J Oral Rehabil. 2004;31:590–594. - PubMed
-
- Bergeron BE, Murchison DF, Schindler WG, Walker WA., 3rd Effect of ultrasonic vibration and various sealer and cement combinations on titanium post removal. J Endod. 2001;27:13–17. - PubMed
-
- Braga NM, Alfredo E, Vansan LP, Fonseca TS, Ferraz JA, Sousa-Neto MD. Efficacy of ultrasound in removal of intraradicular posts using different techniques. J Oral Sci. 2005;47:117–121. - PubMed
-
- Budd JC, Gekelman D, White JM. Temperature rise of the post and on the root surface during ultrasonic post removal. Int Endod J. 2005;38:705–711. - PubMed
-
- Buoncristiani J, Seto BG, Caputo AA. Evaluation of ultrasonic and sonic instruments for intraradicular post removal. J Endod. 1994;20:486–489. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous