. 2010 Nov-Dec;16(6):254-8.
doi: 10.1111/j.1751-7133.2010.00187.x. Epub 2010 Oct 19.

Peak cardiac power measured noninvasively with a bioreactance technique is a predictor of adverse outcomes in patients with advanced heart failure

Affiliations

Peak cardiac power measured noninvasively with a bioreactance technique is a predictor of adverse outcomes in patients with advanced heart failure

Hannah Rosenblum et al. Congest Heart Fail. 2010 Nov-Dec.

Abstract

Peak oxygen consumption (VO(2) ) during cardiopulmonary exercise testing (CPET) is a powerful predictor of survival, providing an indirect assessment of cardiac output (CO). Noninvasive indices of CO derived from bioreactance methodology would add significantly to peak VO(2) as a means of risk-stratifying patients with heart failure. In this study, 127 patients (53 ± 14 years of age, 66% male) with heart failure and an average ejection fraction of 31% ± 15% underwent symptom-limited CPET using a bicycle ergometer while measuring CO noninvasively by a bioreactance technique. Peak cardiac power was derived from the product of the peak mean arterial blood pressure and CO divided by 451. Follow-up averaged 404 ± 179 days (median, 366 days) to assess endpoints including death (n=3), heart transplant (n=10), or left ventricular assisted device implantation (n=2). Peak VO(2) and peak power had similar areas under the curve (0.77 and 0.76), which increased to 0.83 when combined. Kaplan-Meier cumulative survival curves demonstrated different outcomes in the subgroup with a VO(2) <14 mL/kg/min when stratified by a cardiac power above or below 1.5 W (92.2% vs 82.1% at 1 year and 81.6% vs 58.3% at last follow-up, P=.02 by log-rank test). Among patients with heart failure, peak cardiac power measured with bioreactance methodology and peak VO(2) had similar associations with adverse outcomes and peak power added independent prognostic information to peak VO(2) in those with advanced disease (eg, VO(2) <14 mL/kg/min).

PubMed Disclaimer

Figures

Figure 1
Figure 1
Receiver Operating Curves for Peak VO2 and Peak Cardiac Power and their combination.
Figure 2
Figure 2
Kaplan Meier Survival Analysis among subjects with peak VO2 < 14 ml*kg-1*min-1 stratified by peak power > or < 1.5 Watts.

Similar articles

Cited by

References

    1. Mancini D, Katz S, Donchez L, Aaronson K. Coupling of hemodynamic measurements with oxygen consumption during exercise does not improve risk stratification in patients with heart failure. Circulation. 1996;94:2492–6. - PubMed
    1. Wilson JR, Rayos G, Yeoh TK, Gothard P. Dissociation between peak exercise oxygen consumption and hemodynamic dysfunction in potential heart transplant candidates. J Am Coll Cardiol. 1995;26:429–35. - PubMed
    1. Tan LB. Cardiac pumping capability and prognosis in heart failure. Lancet. 1986;2:1360–3. - PubMed
    1. Griffin BP, Shah PK, Ferguson J, Rubin SA. Incremental prognostic value of exercise hemodynamic variables in chronic congestive heart failure secondary to coronary artery disease or to dilated cardiomyopathy. Am J Cardiol. 1991;67:848–53. - PubMed
    1. Roul G, Moulichon ME, Bareiss P, et al. Prognostic factors of chronic heart failure in NYHA class II or III: value of invasive exercise haemodynamic data. Eur Heart J. 1995;16:1387–98. - PubMed

Publication types

MeSH terms