Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2012 Apr;22(2):111-7.
doi: 10.1111/j.1552-6569.2010.00532.x. Epub 2010 Nov 17.

Diagnostic performance of myocardial innervation imaging using MIBG scintigraphy in differential diagnosis between dementia with lewy bodies and other dementias: a systematic review and a meta-analysis

Affiliations
Meta-Analysis

Diagnostic performance of myocardial innervation imaging using MIBG scintigraphy in differential diagnosis between dementia with lewy bodies and other dementias: a systematic review and a meta-analysis

Giorgio Treglia et al. J Neuroimaging. 2012 Apr.

Abstract

Background and purpose: This study was designed to review the diagnostic performance of myocardial innervation imaging using iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy in differential diagnosis between dementia with Lewy bodies (DLB) and other dementias.

Methods: A comprehensive computer literature search of studies published through May 2010 regarding MIBG scintigraphy in patients with DLB was performed in PubMed/MEDLINE and Embase databases. Only studies in which MIBG scintigraphy was performed for differential diagnosis between DLB and other dementias were selected. Pooled sensitivity and specificity of MIBG scintigraphy were presented with a 95% confidence interval (CI). The area under the ROC curve was calculated to measure the accuracy of MIBG scintigraphy in differential diagnosis between Lewy body diseases and other dementias.

Results: Ultimately, we identified 8 studies comprising a total of 346 patients with dementia (152 patients with DLB and 194 patients with other dementias). The pooled sensitivity of MIBG scintigraphy in detection of DLB was 98% (95% CI, 94-100%); the pooled specificity of MIBG scintigraphy in differential diagnosis between DLB and other dementias was 94% (95% CI, 90-97%). The area under the ROC curve was .99.

Conclusions: Myocardial innervation imaging with MIBG scintigraphy demonstrated high pooled sensitivity and specificity in patients with suspected DLB. MIBG scintigraphy is an accurate test for differential diagnosis between DLB and other dementias.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms