Fluorine-18 deoxyglucose positron emission tomography, magnetic resonance imaging and bone scintigraphy for the diagnosis of bone metastases in patients with lung cancer: which one is the best?--a meta-analysis
- PMID: 21094027
- DOI: 10.1016/j.clon.2010.10.002
Fluorine-18 deoxyglucose positron emission tomography, magnetic resonance imaging and bone scintigraphy for the diagnosis of bone metastases in patients with lung cancer: which one is the best?--a meta-analysis
Abstract
Aims: To carry out a meta-analysis to compare fluorine-18 deoxyglucose ((18)FDG) positron emission tomography (PET), magnetic resonance imaging (MRI) and bone scintigraphy imaging for the diagnosis of bone metastases in patients with lung cancer.
Materials and methods: MEDLINE, EMBASE, Scopus and other databases were searched for relevant original articles published between January 1995 and January 2010. Inclusion criteria were as follows: (18)FDG PET, MRI or (99m)Tc-MDP bone scintigraphy was carried out to detect bone metastases in patients with lung cancer; sufficient data were presented to construct a 2×2 contingency table; histopathological analysis and/or close clinical and imaging follow-up and/or radiographic confirmation by multiple imaging modalities were used as the reference standard. Two reviewers independently extracted data. META-DiSc was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves and the *Q index.
Results: In total, 14 articles that consisted of 34 studies fulfilled all inclusion criteria. On a per-patient basis, the pooled sensitivity estimates for PET, MRI and bone scintigraphy were 91.9, 80.0 and 91.8%, respectively. The sensitivity for PET and bone scintigraphy were significantly higher than for MRI (P<0.05). There was no significant difference between PET and bone scintigraphy (P>0.05). The pooled specificity estimates for PET, MRI and bone scintigraphy were 96.8, 90.6 and 68.8%, respectively. The specificity for PET was significantly higher than for MRI and bone scintigraphy (P<0.05), and the specificity for MRI was significantly higher than for bone scintigraphy (P<0.05). The pooled DOR estimates for PET, MRI and bone scintigraphy were 365.5, 53.8 and 34.4, respectively. The DOR for PET was significantly higher than for MRI and bone scintigraphy (P<0.05). There was no significant difference between MRI and bone scintigraphy (P>0.05). The SROC curve for PET showed better diagnostic accuracy than for MRI and bone scintigraphy. The SROC curve for MRI was better than for bone scintigraphy. The *Q index estimates for PET, MRI and bone scintigraphy were 0.933, 0.903 and 0.857, respectively. The *Q index for PET and MRI were significantly higher than for bone scintigraphy (P<0.05). There was no significant difference between PET and MRI (P>0.05). On a per-lesion basis, the pooled sensitivity estimates for PET, MRI and bone scintigraphy were 95.0, 83.8 and 71.5%, respectively. The sensitivity for PET was significantly higher than for MRI and bone scintigraphy (P<0.05), and the sensitivity for MRI was significantly higher than for bone scintigraphy (P<0.05). The pooled specificity estimates for PET, MRI and bone scintigraphy were 94.6, 96.3 and 91.0%, respectively. The specificity for MRI was significantly higher than for PET and bone scintigraphy (P<0.05), and the specificity for PET was significantly higher than for bone scintigraphy (P<0.05). The pooled DOR estimates for PET, MRI and bone scintigraphy were 431.9, 158.1 and 9.0, respectively. The DOR for PET was significantly higher than for MRI and bone scintigraphy (P<0.05) and the DOR for MRI was significantly higher than for bone scintigraphy (P<0.05). The SROC curve for PET and MRI showed better diagnostic accuracy than for bone scintigraphy. There was no significant difference between PET and MRI. The *Q index estimates for PET, MRI and bone scintigraphy were 0.953, 0.962 and 0.778, respectively. The *Q index for PET and MRI were significantly higher than for bone scintigraphy (P<0.05). There was no significant difference between PET and MRI (P>0.05).
Conclusion: (18)FDG PET was found to be the best modality to detect bone metastasis in patients with lung cancer, both on a per-patient basis and a per-lesion basis; MRI had the highest specificity on a per-lesion basis. For the subgroup analysis of (18)FDG PET, PET/computed tomography was shown to be better than PET and there were no significant differences between using (68)Ge and computed tomography for attenuation correction on a per-patient basis.
Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
A meta-analysis of 18FDG-PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with breast cancer.Skeletal Radiol. 2011 May;40(5):523-31. doi: 10.1007/s00256-010-0963-8. Epub 2010 May 22. Skeletal Radiol. 2011. PMID: 20495798
-
Meta-analysis: comparison of F-18 fluorodeoxyglucose-positron emission tomography and bone scintigraphy in the detection of bone metastasis in patients with lung cancer.Acad Radiol. 2012 Mar;19(3):349-57. doi: 10.1016/j.acra.2011.10.018. Epub 2011 Dec 14. Acad Radiol. 2012. PMID: 22173321 Review.
-
A meta-analysis of ¹⁸FDG-PET-CT, ¹⁸FDG-PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with lung cancer.Eur J Radiol. 2012 May;81(5):1007-15. doi: 10.1016/j.ejrad.2011.01.126. Epub 2011 Feb 26. Eur J Radiol. 2012. PMID: 21354739 Review.
-
Detection of vertebral metastases: a meta-analysis comparing MRI, CT, PET, BS and BS with SPECT.J Cancer Res Clin Oncol. 2017 Mar;143(3):457-465. doi: 10.1007/s00432-016-2288-z. Epub 2016 Oct 17. J Cancer Res Clin Oncol. 2017. PMID: 27752772 Free PMC article. Review.
-
Diagnosis of bone metastases: a meta-analysis comparing ¹⁸FDG PET, CT, MRI and bone scintigraphy.Eur Radiol. 2011 Dec;21(12):2604-17. doi: 10.1007/s00330-011-2221-4. Epub 2011 Sep 2. Eur Radiol. 2011. PMID: 21887484 Review.
Cited by
-
Comparison of choline-PET/CT, MRI, SPECT, and bone scintigraphy in the diagnosis of bone metastases in patients with prostate cancer: a meta-analysis.Skeletal Radiol. 2014 Nov;43(11):1503-13. doi: 10.1007/s00256-014-1903-9. Epub 2014 May 20. Skeletal Radiol. 2014. PMID: 24841276 Review.
-
Is there any significance of lung cancer histology to compare the diagnostic accuracies of (18)F-FDG-PET/CT and (99m)Tc-MDP BS for the detection of bone metastases in advanced NSCLC?Contemp Oncol (Pozn). 2014;18(2):106-10. doi: 10.5114/wo.2014.42725. Epub 2014 Jun 3. Contemp Oncol (Pozn). 2014. PMID: 24966793 Free PMC article.
-
Whole-body MRI compared with standard pathways for staging metastatic disease in lung and colorectal cancer: the Streamline diagnostic accuracy studies.Health Technol Assess. 2019 Dec;23(66):1-270. doi: 10.3310/hta23660. Health Technol Assess. 2019. PMID: 31855148 Free PMC article. Clinical Trial.
-
Critical considerations on the combined use of ¹⁸F-FDG and ¹⁸F-fluoride for PET assessment of metastatic bone disease.Eur J Nucl Med Mol Imaging. 2013 Aug;40(8):1141-5. doi: 10.1007/s00259-013-2459-y. Epub 2013 May 22. Eur J Nucl Med Mol Imaging. 2013. PMID: 23695838 No abstract available.
-
Comparisons between glucose analogue 2-deoxy-2-((18)F)fluoro-D-glucose and (18)F-sodium fluoride positron emission tomography/computed tomography in breast cancer patients with bone lesions.World J Radiol. 2016 Feb 28;8(2):200-9. doi: 10.4329/wjr.v8.i2.200. World J Radiol. 2016. PMID: 26981229 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical