Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2011 Jun;23(5):350-8.
doi: 10.1016/j.clon.2010.10.002. Epub 2010 Nov 20.

Fluorine-18 deoxyglucose positron emission tomography, magnetic resonance imaging and bone scintigraphy for the diagnosis of bone metastases in patients with lung cancer: which one is the best?--a meta-analysis

Affiliations
Meta-Analysis

Fluorine-18 deoxyglucose positron emission tomography, magnetic resonance imaging and bone scintigraphy for the diagnosis of bone metastases in patients with lung cancer: which one is the best?--a meta-analysis

Tao Liu et al. Clin Oncol (R Coll Radiol). 2011 Jun.

Abstract

Aims: To carry out a meta-analysis to compare fluorine-18 deoxyglucose ((18)FDG) positron emission tomography (PET), magnetic resonance imaging (MRI) and bone scintigraphy imaging for the diagnosis of bone metastases in patients with lung cancer.

Materials and methods: MEDLINE, EMBASE, Scopus and other databases were searched for relevant original articles published between January 1995 and January 2010. Inclusion criteria were as follows: (18)FDG PET, MRI or (99m)Tc-MDP bone scintigraphy was carried out to detect bone metastases in patients with lung cancer; sufficient data were presented to construct a 2×2 contingency table; histopathological analysis and/or close clinical and imaging follow-up and/or radiographic confirmation by multiple imaging modalities were used as the reference standard. Two reviewers independently extracted data. META-DiSc was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves and the *Q index.

Results: In total, 14 articles that consisted of 34 studies fulfilled all inclusion criteria. On a per-patient basis, the pooled sensitivity estimates for PET, MRI and bone scintigraphy were 91.9, 80.0 and 91.8%, respectively. The sensitivity for PET and bone scintigraphy were significantly higher than for MRI (P<0.05). There was no significant difference between PET and bone scintigraphy (P>0.05). The pooled specificity estimates for PET, MRI and bone scintigraphy were 96.8, 90.6 and 68.8%, respectively. The specificity for PET was significantly higher than for MRI and bone scintigraphy (P<0.05), and the specificity for MRI was significantly higher than for bone scintigraphy (P<0.05). The pooled DOR estimates for PET, MRI and bone scintigraphy were 365.5, 53.8 and 34.4, respectively. The DOR for PET was significantly higher than for MRI and bone scintigraphy (P<0.05). There was no significant difference between MRI and bone scintigraphy (P>0.05). The SROC curve for PET showed better diagnostic accuracy than for MRI and bone scintigraphy. The SROC curve for MRI was better than for bone scintigraphy. The *Q index estimates for PET, MRI and bone scintigraphy were 0.933, 0.903 and 0.857, respectively. The *Q index for PET and MRI were significantly higher than for bone scintigraphy (P<0.05). There was no significant difference between PET and MRI (P>0.05). On a per-lesion basis, the pooled sensitivity estimates for PET, MRI and bone scintigraphy were 95.0, 83.8 and 71.5%, respectively. The sensitivity for PET was significantly higher than for MRI and bone scintigraphy (P<0.05), and the sensitivity for MRI was significantly higher than for bone scintigraphy (P<0.05). The pooled specificity estimates for PET, MRI and bone scintigraphy were 94.6, 96.3 and 91.0%, respectively. The specificity for MRI was significantly higher than for PET and bone scintigraphy (P<0.05), and the specificity for PET was significantly higher than for bone scintigraphy (P<0.05). The pooled DOR estimates for PET, MRI and bone scintigraphy were 431.9, 158.1 and 9.0, respectively. The DOR for PET was significantly higher than for MRI and bone scintigraphy (P<0.05) and the DOR for MRI was significantly higher than for bone scintigraphy (P<0.05). The SROC curve for PET and MRI showed better diagnostic accuracy than for bone scintigraphy. There was no significant difference between PET and MRI. The *Q index estimates for PET, MRI and bone scintigraphy were 0.953, 0.962 and 0.778, respectively. The *Q index for PET and MRI were significantly higher than for bone scintigraphy (P<0.05). There was no significant difference between PET and MRI (P>0.05).

Conclusion: (18)FDG PET was found to be the best modality to detect bone metastasis in patients with lung cancer, both on a per-patient basis and a per-lesion basis; MRI had the highest specificity on a per-lesion basis. For the subgroup analysis of (18)FDG PET, PET/computed tomography was shown to be better than PET and there were no significant differences between using (68)Ge and computed tomography for attenuation correction on a per-patient basis.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources