Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study
- PMID: 21098452
- DOI: 10.1161/CIRCULATIONAHA.110.960633
Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study
Abstract
Background: Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a network.
Methods and results: Survival status in patients implanted with ICD and CRT devices across the United States from a single manufacturer was assessed. Outcomes were compared between patients followed in device clinic settings and those who regularly transmit remote data collected from the device an average of 4 times monthly. Shock delivery and electrogram analysis could be ascertained from patients followed on the network, enabling survival after ICD shock to be evaluated. One- and 5-year survival rates in 185,778 patients after ICD implantation were 92% and 68% and were 88% and 54% for CRT-D device recipients. In 8228 patients implanted with CRT-only devices, survival was 82% and 48% at 1 and 5 years, respectively. For the 69,556 ICD and CRT-D patients receiving remote follow-up on the network, 1- and 5-year survival rates were higher compared with those in the 116,222 patients who received device follow-up in device clinics only (50% reduction; P<0.0001). There were no differences between patients followed on or off the remote network for the characteristics of age, gender, implanted device year or type, and economic or educational status. Shock therapy was associated with subsequent mortality risk for both ICD and CRT-D recipients.
Conclusions: Survival after ICD and CRT-D implantation in patients treated in naturalistic practice compares favorably with survival rates observed in clinical trials. Remote follow-up of device data is associated with excellent survival, but arrhythmias that result in device therapy in this population are associated with a higher mortality risk compared with patients who do not require shock therapy.
Comment in
-
Survival of patients with implantable cardioverter defibrillators in the era of remote-monitoring: the 5000-foot, high-altitude view.Circulation. 2010 Dec 7;122(23):2353-5. doi: 10.1161/CIRCULATIONAHA.110.991687. Epub 2010 Nov 22. Circulation. 2010. PMID: 21098454 No abstract available.
Similar articles
-
Survival of patients with implantable cardioverter defibrillators in the era of remote-monitoring: the 5000-foot, high-altitude view.Circulation. 2010 Dec 7;122(23):2353-5. doi: 10.1161/CIRCULATIONAHA.110.991687. Epub 2010 Nov 22. Circulation. 2010. PMID: 21098454 No abstract available.
-
The Relationship Between Level of Adherence to Automatic Wireless Remote Monitoring and Survival in Pacemaker and Defibrillator Patients.J Am Coll Cardiol. 2015 Jun 23;65(24):2601-2610. doi: 10.1016/j.jacc.2015.04.033. Epub 2015 May 13. J Am Coll Cardiol. 2015. PMID: 25983008
-
Acute lead dislodgements and in-hospital mortality in patients enrolled in the national cardiovascular data registry implantable cardioverter defibrillator registry.J Am Coll Cardiol. 2010 Nov 9;56(20):1651-6. doi: 10.1016/j.jacc.2010.06.037. J Am Coll Cardiol. 2010. PMID: 21050975
-
All cause mortality of cardiac resynchronization therapy with implantable cardioverter defibrillator: a meta-analysis of randomized controlled trials.Int J Cardiol. 2010 Dec 3;145(3):413-7. doi: 10.1016/j.ijcard.2010.05.016. Epub 2010 Jun 12. Int J Cardiol. 2010. PMID: 20541819 Review.
-
Is implantable defibrillator indicated in all patients on cardiac resynchronization therapy?Minerva Cardioangiol. 2006 Dec;54(6):735-41. Minerva Cardioangiol. 2006. PMID: 17167385 Review.
Cited by
-
Remote monitoring of cardiac implantable electronic devices (CIED).Trends Cardiovasc Med. 2016 Aug;26(6):568-77. doi: 10.1016/j.tcm.2016.03.012. Epub 2016 Mar 31. Trends Cardiovasc Med. 2016. PMID: 27134007 Free PMC article. Review.
-
Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing.Mayo Clin Proc. 2015 Feb;90(2):202-8. doi: 10.1016/j.mayocp.2014.11.011. Mayo Clin Proc. 2015. PMID: 25659238 Free PMC article.
-
Reduction of inappropriate implantable cardioverter-defibrillator therapies using enhanced supraventricular tachycardia discriminators: the ReduceIT study.J Interv Card Electrophysiol. 2021 Aug;61(2):339-348. doi: 10.1007/s10840-020-00816-9. Epub 2020 Jul 14. J Interv Card Electrophysiol. 2021. PMID: 32661865
-
[Lead survival and complications (except infections). Are we doing better nowadays?].Herzschrittmacherther Elektrophysiol. 2013 Sep;24(3):141-7. doi: 10.1007/s00399-013-0278-2. Epub 2013 Aug 6. Herzschrittmacherther Elektrophysiol. 2013. PMID: 23917591 German.
-
Clinical experience with subcutaneous implantable cardioverter-defibrillators.Nat Rev Cardiol. 2015 Jul;12(7):398-405. doi: 10.1038/nrcardio.2015.56. Epub 2015 Apr 21. Nat Rev Cardiol. 2015. PMID: 25898263 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials