Abstract
Purpose: To report the rate of graft dislocation in patients who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) after a previous penetrating keratoplasty (PKP).
Methods: Institutional review board-approved, multicenter, retrospective chart review. Inclusion criteria included: prior failed PKP and subsequent DSAEK. The primary outcomes measured in this study were the presence of a graft dislocation, rate of rebubble, and graft attachment. Additional variables included: presence of a prior glaucoma drainage device, graft-to-host size disparity, number of sutures remaining in PKP, and stripping of the Descemet membrane at the time of DSAEK surgery.
Results: Ninety patients (97 eyes) were included in the study. In 31% (30 of 97), the endothelial graft dislocated after surgery. All 30 cases required a rebubble except 1, which reattached spontaneously. Ninety-eight percent (95 of 97) of all grafts remained attached for the duration of the follow-up period. Only 2 eyes (2.2%) required repeat graft. Endothelial grafts dislocated in 67% of patients with glaucoma draining devices. The dislocation rate for grafts larger than the host was 12 of 49 (24%), equal to the host was 3 of 17 (18%), and smaller than the host was 8 of 19 (42%). Dislocations occurred in 5 of 21 (24%) of grafts with sutures remaining and 22 of 76 (29%) of those with all sutures out. Five of 12 (42%) cases of grafts performed without stripping the Descemet had dislocations.
Conclusions: The graft dislocation rate in DSAEK procedures after PKP is comparable to that after primary DSAEK cases. Donor grafts that are smaller than the host PKP and the presence of prior glaucoma drainage devices are risk factors for higher rates of graft dislocation.
Similar articles
-
Failed descemet-stripping automated endothelial keratoplasty grafts: a clinicopathologic analysis.Am J Ophthalmol. 2009 Nov;148(5):752-759.e2. doi: 10.1016/j.ajo.2009.06.023. Epub 2009 Aug 11. Am J Ophthalmol. 2009. PMID: 19674726
-
Secondary graft failure and repeat endothelial keratoplasty after Descemet's stripping automated endothelial keratoplasty.Ophthalmology. 2011 Feb;118(2):310-4. doi: 10.1016/j.ophtha.2010.06.032. Ophthalmology. 2011. PMID: 20869118
-
Descemet's stripping automated endothelial keratoplasty and penetrating keratoplasty for Fuchs' endothelial dystrophy.Acta Ophthalmol. 2009 May;87(3):310-4. doi: 10.1111/j.1755-3768.2008.01492.x. Epub 2009 Mar 19. Acta Ophthalmol. 2009. PMID: 19302079
-
Descemet stripping automated endothelial keratoplasty in a child after failed penetrating keratoplasty.J AAPOS. 2012 Feb;16(1):95-6. doi: 10.1016/j.jaapos.2011.09.009. Epub 2012 Jan 11. J AAPOS. 2012. PMID: 22244506 Review.
-
What DSAEK is going on? An alternative to penetrating keratoplasty for endothelial dysfunction.Optometry. 2009 Sep;80(9):513-23. doi: 10.1016/j.optm.2008.11.010. Optometry. 2009. PMID: 19716079 Review.
Cited by
-
Ophthalmic transplantology: anterior segment of the eye - part I.Med Sci Monit. 2012 May;18(5):RA64-72. doi: 10.12659/msm.882723. Med Sci Monit. 2012. PMID: 22534721 Free PMC article.
-
Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty.Clin Ophthalmol. 2015 Feb 10;9:277-83. doi: 10.2147/OPTH.S78930. eCollection 2015. Clin Ophthalmol. 2015. PMID: 25709389 Free PMC article.
-
Outcome of Descemet stripping automated endothelial keratoplasty in eyes with an Ahmed glaucoma valve.Graefes Arch Clin Exp Ophthalmol. 2017 May;255(5):987-993. doi: 10.1007/s00417-017-3612-2. Epub 2017 Mar 17. Graefes Arch Clin Exp Ophthalmol. 2017. PMID: 28314955
-
The outcome of 70/30 taco insertion through a 2.8 mm clear corneal incision in Descemet's stripping automated endothelial keratoplasty - A retrospective analysis.Indian J Ophthalmol. 2022 Jan;70(1):95-99. doi: 10.4103/ijo.IJO_663_21. Indian J Ophthalmol. 2022. PMID: 34937216 Free PMC article.
-
Outcome of Descemet Stripping Automated Endothelial Keratoplasty in Failed Penetrating Keratoplasty.Middle East Afr J Ophthalmol. 2017 Apr-Jun;24(2):87-90. doi: 10.4103/meajo.MEAJO_248_15. Middle East Afr J Ophthalmol. 2017. PMID: 28936052 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical