Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 - history, principles and efficiency
- PMID: 21106035
- DOI: 10.1111/j.1365-2044.2010.06563.x
Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 - history, principles and efficiency
Abstract
Heat and moisture exchangers and breathing system filters are intended to replace the normal warming, humidifying and filtering functions of the upper airways when these structures are bypassed during anaesthesia and intensive care. Guidance on their use continues to evolve. The aim of this part of the review is to describe the principles of their action and efficiency and to summarise the findings from clinical and laboratory studies. Based on previous studies, an appropriate minimum target for moisture output is 30 and 20 g.m⁻³ for long-duration use in intensive care and short-duration use in anaesthesia, respectively. The practice of reusing a breathing system in anaesthesia, provided it is protected by a filter, assumes that the filter is effective. However, there is wide variation in the gas-borne filtration performance, and contaminated condensate can potentially pass through some filters under typical pressures encountered during mechanical ventilation.
© 2010 The Author. Anaesthesia © 2010 The Association of Anaesthetists of Great Britain and Ireland.
Similar articles
-
Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 - practical use, including problems, and their use with paediatric patients.Anaesthesia. 2011 Jan;66(1):40-51. doi: 10.1111/j.1365-2044.2010.06564.x. Epub 2010 Nov 30. Anaesthesia. 2011. PMID: 21118189 Review.
-
Passage of pathogenic microorganisms through breathing system filters used in anaesthesia and intensive care.Anaesthesia. 2010 Jul;65(7):670-3. doi: 10.1111/j.1365-2044.2010.06327.x. Epub 2010 Apr 1. Anaesthesia. 2010. PMID: 20374232
-
The use of filters with small infants.Respir Care Clin N Am. 2006 Jun;12(2):307-20. doi: 10.1016/j.rcc.2006.03.006. Respir Care Clin N Am. 2006. PMID: 16828697 Review.
-
Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.J Indian Med Assoc. 2008 Aug;106(8):533-5, 537. J Indian Med Assoc. 2008. PMID: 18975515
-
Heat and moisture exchangers and breathing filters.Br J Anaesth. 1994 Aug;73(2):227-36. doi: 10.1093/bja/73.2.227. Br J Anaesth. 1994. PMID: 7917741 Review. No abstract available.
Cited by
-
Effect of heat and moisture exchangers on the prevention of ventilator-associated pneumonia in critically ill patients.Braz J Med Biol Res. 2012 Dec;45(12):1295-300. doi: 10.1590/s0100-879x2012007500161. Epub 2012 Oct 9. Braz J Med Biol Res. 2012. PMID: 23044627 Free PMC article.
-
Effects of breathing circuit insulation on inspired gas conditioning and water vapour condensation: an in vitro study.Can J Anaesth. 2025 May;72(5):780-790. doi: 10.1007/s12630-025-02959-7. Epub 2025 May 21. Can J Anaesth. 2025. PMID: 40399737 Free PMC article.
-
Preparing your intensive care unit for the COVID-19 pandemic: practical considerations and strategies.Crit Care. 2020 May 11;24(1):215. doi: 10.1186/s13054-020-02916-4. Crit Care. 2020. PMID: 32393325 Free PMC article. Review.
-
Making respiratory care safe for neonatal and paediatric intensive care unit staff: mitigation strategies and use of filters.Can J Respir Ther. 2024 Jan 22;60:13-27. doi: 10.29390/001c.91262. eCollection 2024. Can J Respir Ther. 2024. PMID: 38384335 Free PMC article.
-
Endo tracheal tube exchange in a COVID positive patient.J Clin Anesth. 2020 Nov;66:109941. doi: 10.1016/j.jclinane.2020.109941. Epub 2020 Jun 12. J Clin Anesth. 2020. PMID: 32540724 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical