Initial experience of mitral valve repair using the Carpentier-Edwards Physio II annuloplasty ring
- PMID: 21106384
- DOI: 10.1016/j.ejcts.2010.10.004
Initial experience of mitral valve repair using the Carpentier-Edwards Physio II annuloplasty ring
Abstract
Objective: The Carpentier-Edwards (CE) Physio II ring is a new prosthetic ring designed to accommodate the changing pathology seen in the spectrum of degenerative valve disease, particularly the larger anterior leaflet in repair of the Barlow valve. The aim of our study was to assess the safety and efficacy of mitral valve (MV) repair with the CE Physio II ring.
Methods: Between April 2009 and March 2010, 100 patients underwent MV repair using the Physio II ring. Median age of patients was 70 years (54-85 years). The left ventricle (LV) was moderately (30-50%; n=21) or severely (<30%; n=6) impaired in 27 patients preoperatively. Mitral regurgitation (MR) was due to degenerative disease in 87 patients (bileaflet prolapse: 34 patients). Mean logistic EuroSCORE was 10.07 ± 8.9 and mean follow-up was 6.3 ± 2.4 months.
Results: Seventeen patients were non-elective (eight emergencies), five were re-do operations and 23 Maze ± pulmonary vein isolations, and 14 tricuspid annuloplasties were performed. Neo-chordae were inserted in 50 patients (50%), whereas sliding annuloplasty was performed only in three patients. The median ring size was 32 mm (range 26-40 mm). On-table trans-oesophageal echocardiography (TOE) showed trivial/no MR in 87 patients, and mild in 13 patients, and there were no cases of systolic anterior motion (SAM). There were two re-explorations for bleeding and two patients required haemofiltration. There were no strokes or deep sternal wound infections (DSWIs). There was one hospital death (1%). At discharge, mean left ventricular end-diastolic (LVEDD) was 4.8 ± 0.7 cm compared with 5.5 ± 0.8 cm preoperatively (p=0.03) and mean left ventricular end-systolic (LVESD) was 3.3 ± 0.5 cm as compared with 3.6 ± 0.8 preoperatively (p=0.4). There was no MR in 87 patients and mild MR in 13 patients. The mean mitral valve area (MVA) was 2.8 ± 0.7 cm(2). The mean systolic pulmonary artery pressure (SPAP) was 26.6 ± 7.3 mmHg as compared with 50.9 ± 17.2 mmHg preoperatively (p=0.02). During follow-up, there were no thrombo-embolic complications, re-operation, endocarditis or deaths.
Conclusions: MV repair with the Physio II ring has excellent short-term results, including subgroups with large anterior mitral valve leaflet (AMVL). Moreover, the dimensional ratios of the ring may allow it to be used for MV repair for degenerative MV disease, irrespective of anterior leaflet size.
Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.
Similar articles
-
Mitral valve repair for severe mitral regurgitation secondary to lone atrial fibrillation.Eur J Cardiothorac Surg. 2012 Oct;42(4):634-7. doi: 10.1093/ejcts/ezs029. Epub 2012 Feb 8. Eur J Cardiothorac Surg. 2012. PMID: 22323495
-
Simple repair approach for mitral regurgitation in Barlow disease.J Thorac Cardiovasc Surg. 2015 Nov;150(5):1071-7.e1. doi: 10.1016/j.jtcvs.2015.08.023. Epub 2015 Aug 13. J Thorac Cardiovasc Surg. 2015. PMID: 26384751
-
The GeoForm annuloplasty ring for the surgical treatment of functional mitral regurgitation in advanced dilated cardiomyopathy.Eur J Cardiothorac Surg. 2011 Aug;40(2):488-95. doi: 10.1016/j.ejcts.2010.11.048. Epub 2011 Jan 12. Eur J Cardiothorac Surg. 2011. PMID: 21232967
-
[Initial results of mitral valvuloplasty using the Physio-Carpentier-Edwards ring].Arch Mal Coeur Vaiss. 1997 Jun;90(6):789-95. Arch Mal Coeur Vaiss. 1997. PMID: 9295931 Review. French.
-
Systematic evaluation of the flexible and rigid annuloplasty ring after mitral valve repair for mitral regurgitation.Eur J Cardiothorac Surg. 2011 Aug;40(2):480-7. doi: 10.1016/j.ejcts.2010.11.080. Epub 2011 Feb 3. Eur J Cardiothorac Surg. 2011. PMID: 21295489
Cited by
-
Effect of mitral annuloplasty device shape and size on leaflet and myofiber stress following repair of posterior leaflet prolapse: a patient-specific finite element simulation.J Heart Valve Dis. 2014 Nov;23(6):727-34. J Heart Valve Dis. 2014. PMID: 25790620 Free PMC article.
-
Computational virtual evaluation of the effect of annuloplasty ring shape.Int J Numer Method Biomed Eng. 2017 Jun;33(6):10.1002/cnm.2831. doi: 10.1002/cnm.2831. Epub 2016 Oct 5. Int J Numer Method Biomed Eng. 2017. PMID: 27603720 Free PMC article.
-
Virtual downsizing for decision support in mitral valve repair.Int J Comput Assist Radiol Surg. 2019 Feb;14(2):357-371. doi: 10.1007/s11548-018-1868-6. Epub 2018 Oct 6. Int J Comput Assist Radiol Surg. 2019. PMID: 30293173
-
In-vivo analysis of selectively flexible mitral annuloplasty rings using three-dimensional echocardiography.Ann Thorac Surg. 2014 Jun;97(6):2005-10. doi: 10.1016/j.athoracsur.2014.01.012. Epub 2014 Mar 6. Ann Thorac Surg. 2014. PMID: 24612703 Free PMC article.
-
Annular dynamics after mitral valve repair with different prosthetic rings: A real-time three-dimensional transesophageal echocardiography study.Surg Today. 2016 Sep;46(9):1083-90. doi: 10.1007/s00595-015-1279-z. Epub 2015 Dec 21. Surg Today. 2016. PMID: 26687280