Comparison of acceleration signals of simulated and real-world backward falls
- PMID: 21123104
- DOI: 10.1016/j.medengphy.2010.11.003
Comparison of acceleration signals of simulated and real-world backward falls
Abstract
Most of the knowledge on falls of older persons has been obtained from oral reports that might be biased in many ways. Fall simulations are widely used to gain insight into circumstances of falls, but the results, at least concerning fall detection, are not convincing. Variation of acceleration and maximum jerk of 5 real-world backward falls of 4 older persons (mean age 68.8 years) were compared to the corresponding signals of simulated backward falls by 18 healthy students. Students were instructed to "fall to the back as if you were a frail old person" during experiment 1. In experiment 2, students were instructed not to fall, if possible, when released from a backward lean. Data acquisition was performed using a tri-axial acceleration sensor. In experiment 1, there was significantly more variation within the acceleration signals and maximum jerk was higher in the real-world falls, compared to the fall simulation. Conversely, all values of acceleration and jerk were higher for the fall simulations, compared to real-world falls in experiment 2. The present findings demonstrate differences between real-world falls and fall simulations. If fall simulations are used, their limitations should be noted and the protocol should be adapted to better match real-world falls.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Comparison of real-life accidental falls in older people with experimental falls in middle-aged test subjects.Gait Posture. 2012 Mar;35(3):500-5. doi: 10.1016/j.gaitpost.2011.11.016. Epub 2011 Dec 12. Gait Posture. 2012. PMID: 22169389
-
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm.Gait Posture. 2007 Jul;26(2):194-9. doi: 10.1016/j.gaitpost.2006.09.012. Epub 2006 Nov 13. Gait Posture. 2007. PMID: 17101272
-
A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration.Physiol Meas. 2009 Oct;30(10):1027-37. doi: 10.1088/0967-3334/30/10/004. Epub 2009 Aug 28. Physiol Meas. 2009. PMID: 19713595
-
Methods for the Real-World Evaluation of Fall Detection Technology: A Scoping Review.Sensors (Basel). 2018 Jun 27;18(7):2060. doi: 10.3390/s18072060. Sensors (Basel). 2018. PMID: 29954155 Free PMC article.
-
2016 ASMS Fall Workshop: Sample Preparation for the Real-World Analysis of Samples by Mass Spectrometry.J Am Soc Mass Spectrom. 2017 Mar;28(3):395-398. doi: 10.1007/s13361-016-1568-9. J Am Soc Mass Spectrom. 2017. PMID: 28050873 Review. No abstract available.
Cited by
-
Analysis of Android Device-Based Solutions for Fall Detection.Sensors (Basel). 2015 Jul 23;15(8):17827-94. doi: 10.3390/s150817827. Sensors (Basel). 2015. PMID: 26213928 Free PMC article. Review.
-
Evaluation of accelerometer-based fall detection algorithms on real-world falls.PLoS One. 2012;7(5):e37062. doi: 10.1371/journal.pone.0037062. Epub 2012 May 16. PLoS One. 2012. PMID: 22615890 Free PMC article.
-
Sit-stand and stand-sit transitions in older adults and patients with Parkinson's disease: event detection based on motion sensors versus force plates.J Neuroeng Rehabil. 2012 Oct 7;9:75. doi: 10.1186/1743-0003-9-75. J Neuroeng Rehabil. 2012. PMID: 23039219 Free PMC article.
-
Estimation of Foot Plantar Center of Pressure Trajectories with Low-Cost Instrumented Insoles Using an Individual-Specific Nonlinear Model.Sensors (Basel). 2018 Feb 1;18(2):421. doi: 10.3390/s18020421. Sensors (Basel). 2018. PMID: 29389857 Free PMC article.
-
Fall detection with body-worn sensors : a systematic review.Z Gerontol Geriatr. 2013 Dec;46(8):706-19. doi: 10.1007/s00391-013-0559-8. Z Gerontol Geriatr. 2013. PMID: 24271251
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical