Analysis: high-tech diabetes technology and the myth of clinical "plug and play"
- PMID: 21129342
- PMCID: PMC3005057
- DOI: 10.1177/193229681000400621
Analysis: high-tech diabetes technology and the myth of clinical "plug and play"
Abstract
In this issue of Journal of Diabetes Science and Technology, Davey and coauthors present encouraging data that even short-term use of a real-time continuous glucose monitor can lead to marked reduction in hypoglycemia exposure. In this analysis, two particular issues will be discussed: the distinction between short- and long-term experiences with sensors and the use of standardized diabetes treatment algorithms for use with continuous glucose monitoring (CGM) devices. An understanding of both of these aspects of CGM devices is necessary for placing clinical diabetes technology products into the context of how they will be used in "real life."
© 2010 Diabetes Technology Society.
Comment on
-
Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.J Diabetes Sci Technol. 2010 Nov 1;4(6):1457-64. doi: 10.1177/193229681000400620. J Diabetes Sci Technol. 2010. PMID: 21129341 Free PMC article. Clinical Trial.
Similar articles
-
Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.J Diabetes Sci Technol. 2010 Nov 1;4(6):1457-64. doi: 10.1177/193229681000400620. J Diabetes Sci Technol. 2010. PMID: 21129341 Free PMC article. Clinical Trial.
-
Relationships among different glycemic variability indices obtained by continuous glucose monitoring.Prim Care Diabetes. 2015 Aug;9(4):290-6. doi: 10.1016/j.pcd.2014.10.001. Epub 2014 Nov 16. Prim Care Diabetes. 2015. PMID: 25456706
-
Simple Post-Processing of Continuous Glucose Monitoring Measurements Improves Endpoints in Clinical Trials.J Diabetes Sci Technol. 2020 Nov;14(6):1074-1078. doi: 10.1177/1932296819848721. Epub 2019 May 16. J Diabetes Sci Technol. 2020. PMID: 31096765 Free PMC article.
-
Clinical requirements for closed-loop control systems.J Diabetes Sci Technol. 2012 Mar 1;6(2):444-52. doi: 10.1177/193229681200600233. J Diabetes Sci Technol. 2012. PMID: 22538159 Free PMC article. Review.
-
[Hypoglycemia--simply annoying or dangerous?].MMW Fortschr Med. 2016 Jun 9;158(11):67-70. doi: 10.1007/s15006-016-8385-8. MMW Fortschr Med. 2016. PMID: 27271419 Review. German. No abstract available.
Cited by
-
The JDRF CCTN CGM TIME Trial: Timing of Initiation of continuous glucose Monitoring in Established pediatric type 1 diabetes: study protocol, recruitment and baseline characteristics.BMC Pediatr. 2014 Jul 18;14:183. doi: 10.1186/1471-2431-14-183. BMC Pediatr. 2014. PMID: 25034216 Free PMC article. Clinical Trial.
-
"Turn it off!": diabetes device alarm fatigue considerations for the present and the future.J Diabetes Sci Technol. 2013 May 1;7(3):789-94. doi: 10.1177/193229681300700324. J Diabetes Sci Technol. 2013. PMID: 23759412 Free PMC article.
References
-
- Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, Parkin CG, Wolpert HA, Buckingham BA. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther. 2008;10(5):377–383. - PubMed
-
- Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O’Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med. 2008;359(14):1464–1476. - PubMed
-
- Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA, STAR 3 Study Group Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010;363(11):311–320. - PubMed
-
- Davey RJ, Jones TW, Fournier PA. Effect of short term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus. J Diabetes Sci Technol. 2010;4(6):1457–1464. - PMC - PubMed
-
- Diabetes Research in Children Network (DirecNet) Study Group. Buckingham B, Beck RW, Tamborlane WV, Xing D, Kollman C, Fiallo-Scharer R, Mauras N, Ruedy KJ, Tansey M, Weinzimer SA, Wysocki T. Continuous glucose monitoring in children with type 1 diabetes. J Pediatr. 2007;151(4):388–393. 393.e1-2. Epub 2007 Aug 24. - PMC - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical