Analysis: high-tech diabetes technology and the myth of clinical "plug and play"
- PMID: 21129342
- PMCID: PMC3005057
- DOI: 10.1177/193229681000400621
Analysis: high-tech diabetes technology and the myth of clinical "plug and play"
Abstract
In this issue of Journal of Diabetes Science and Technology, Davey and coauthors present encouraging data that even short-term use of a real-time continuous glucose monitor can lead to marked reduction in hypoglycemia exposure. In this analysis, two particular issues will be discussed: the distinction between short- and long-term experiences with sensors and the use of standardized diabetes treatment algorithms for use with continuous glucose monitoring (CGM) devices. An understanding of both of these aspects of CGM devices is necessary for placing clinical diabetes technology products into the context of how they will be used in "real life."
© 2010 Diabetes Technology Society.
Comment on
-
Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.J Diabetes Sci Technol. 2010 Nov 1;4(6):1457-64. doi: 10.1177/193229681000400620. J Diabetes Sci Technol. 2010. PMID: 21129341 Free PMC article. Clinical Trial.
References
-
- Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, Parkin CG, Wolpert HA, Buckingham BA. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther. 2008;10(5):377–383. - PubMed
-
- Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O’Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med. 2008;359(14):1464–1476. - PubMed
-
- Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA, STAR 3 Study Group Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010;363(11):311–320. - PubMed
-
- Davey RJ, Jones TW, Fournier PA. Effect of short term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus. J Diabetes Sci Technol. 2010;4(6):1457–1464. - PMC - PubMed
-
- Diabetes Research in Children Network (DirecNet) Study Group. Buckingham B, Beck RW, Tamborlane WV, Xing D, Kollman C, Fiallo-Scharer R, Mauras N, Ruedy KJ, Tansey M, Weinzimer SA, Wysocki T. Continuous glucose monitoring in children with type 1 diabetes. J Pediatr. 2007;151(4):388–393. 393.e1-2. Epub 2007 Aug 24. - PMC - PubMed
Publication types