Angiopoietin-1 and endostatin levels in cord plasma predict the development of bronchopulmonary dysplasia in preterm infants
- PMID: 21131270
- DOI: 10.1093/tropej/fmq112
Angiopoietin-1 and endostatin levels in cord plasma predict the development of bronchopulmonary dysplasia in preterm infants
Abstract
Objective: To determine whether angiopoietin-1 and endostatin levels in the cord blood could predict the subsequent development of bronchopulmonary dysplasia (BPD) in preterm infants.
Patients and methods: A total of 102 preterm (gestational age ≤ 32 weeks) infants (28 infants developed BPD and 74 had no BPD) were enrolled in the study. Cord plasma levels of angiopoietin-1 and endostatin were measured by enzyme-linked immunosorbent assay.
Results: Preterm infants who subsequently developed BPD had significantly lower cord plasma levels of angiopoietin-1 than those who did not (p < 0.001). Our results showed that cord plasma levels of endostatin were significantly higher in infants with BPD than in those without (p < 0.001). In infants with BPD, angiopoietin-1 levels in cord plasma correlated negatively with endostatin (r = -0.48; p = 0.008).
Conclusion: In preterm infants, low-angiopoietin-1 and high-endostatin levels in cord plasma at birth predict the subsequent development of BPD.
Similar articles
-
Endostatin concentration in cord plasma predicts the development of bronchopulmonary dysplasia in very low birth weight infants.Pediatrics. 2009 Apr;123(4):1142-6. doi: 10.1542/peds.2008-1339. Pediatrics. 2009. PMID: 19336373
-
Serial changes of serum endostatin and angiopoietin-1 levels in preterm infants with severe bronchopulmonary dysplasia and subsequent pulmonary artery hypertension.Neonatology. 2014;106(1):55-61. doi: 10.1159/000358374. Epub 2014 May 7. Neonatology. 2014. PMID: 24818792
-
Cord blood fibroblast growth factor-10 as a possible predictor of bronchopulmonary dysplasia in preterm infants.J Neonatal Perinatal Med. 2014 Jan 1;7(2):101-5. doi: 10.3233/NPM-1476613. J Neonatal Perinatal Med. 2014. PMID: 25104125
-
Biomarkers in bronchopulmonary dysplasia.Paediatr Respir Rev. 2013 Sep;14(3):173-9. doi: 10.1016/j.prrv.2013.02.008. Epub 2013 Mar 21. Paediatr Respir Rev. 2013. PMID: 23523392 Review.
-
Predictive value of platelet parameters for bronchopulmonary dysplasia in preterm infants: A systematic review and meta-analysis.Medicine (Baltimore). 2024 Dec 27;103(52):e41083. doi: 10.1097/MD.0000000000041083. Medicine (Baltimore). 2024. PMID: 39969323 Free PMC article.
Cited by
-
Bronchopulmonary dysplasia.Nat Rev Dis Primers. 2019 Nov 14;5(1):78. doi: 10.1038/s41572-019-0127-7. Nat Rev Dis Primers. 2019. PMID: 31727986 Free PMC article. Review.
-
The vascular phenotype of BPD: new basic science insights-new precision medicine approaches.Pediatr Res. 2024 Oct;96(5):1162-1171. doi: 10.1038/s41390-022-02428-7. Epub 2022 Dec 22. Pediatr Res. 2024. PMID: 36550351 Review.
-
Inflammatory and Immune Proteins in Umbilical Cord Blood: Association with Hearing Screening Test Failure in Preterm Neonates.Mediators Inflamm. 2018 Sep 19;2018:4209359. doi: 10.1155/2018/4209359. eCollection 2018. Mediators Inflamm. 2018. PMID: 30327582 Free PMC article.
-
Early prediction of bronchopulmonary dysplasia: can noninvasive monitoring methods be essential?ERJ Open Res. 2023 Apr 3;9(2):00621-2022. doi: 10.1183/23120541.00621-2022. eCollection 2023 Mar. ERJ Open Res. 2023. PMID: 37020839 Free PMC article. Review.
-
Proinflammatory Endothelial Phenotype in Very Preterm Infants: A Pilot Study.Biomedicines. 2022 May 20;10(5):1185. doi: 10.3390/biomedicines10051185. Biomedicines. 2022. PMID: 35625922 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources