Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2010 Dec;22(6):493-8.
doi: 10.1111/j.1742-6723.2010.01344.x.

Review article: Can venous blood gas analysis replace arterial in emergency medical care

Affiliations
Review

Review article: Can venous blood gas analysis replace arterial in emergency medical care

Anne-Maree Kelly. Emerg Med Australas. 2010 Dec.

Abstract

The objectives of the present review are to describe the agreement between variables on arterial and venous blood gas analysis (in particular pH, pCO(2) , bicarbonate and base excess) and to identify unanswered questions. MEDLINE search of papers published from 1966 to January 2010 for studies comparing arterial and peripheral venous blood gas values for any of pH, pCO(2) , bicarbonate and base excess in adult patients with any condition in an emergency department setting. The outcome of interest was mean difference weighted for study sample size with 95% limits of agreement. The weighted mean arterio-venous difference in pH was 0.035 pH units (n= 1252), with narrow limits of agreement. The weighted mean arterio-venous difference for pCO(2) was 5.7 mmHg (n= 760), but with 95% limits of agreement up to the order of ±20 mmHg. For bicarbonate, the weighted mean difference between arterial and venous values was -1.41 mmol/L (n= 905), with 95% limits of agreement of the order of ±5 mmol/L. Regarding base excess, the mean arterio-venous difference is 0.089 mmol/L (n= 103). There is insufficient data to determine if these relationships persist in shocked patients or those with mixed acid-base disorders. For patients who are not in shock, venous pH, bicarbonate and base excess have sufficient agreement to be clinically interchangeable for arterial values. Agreement between arterial and venous pCO(2) is too poor and unpredictable to be clinically useful as a one-off test but venous pCO(2) might be useful to screen for arterial hypercarbia or to monitor trends in pCO(2) for selected patients.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources