Comparative Study
. 2011 Feb;49(2):557-64.
doi: 10.1128/JCM.02147-10. Epub 2010 Dec 8.

Aptima HPV E6/E7 mRNA test is as sensitive as Hybrid Capture 2 Assay but more specific at detecting cervical precancer and cancer

Affiliations
Comparative Study

Aptima HPV E6/E7 mRNA test is as sensitive as Hybrid Capture 2 Assay but more specific at detecting cervical precancer and cancer

Samuel Ratnam et al. J Clin Microbiol. 2011 Feb.

Abstract

Detection of human papillomavirus (HPV) E6/E7 oncogene expression may be more predictive of cervical cancer risk than testing for HPV DNA. The Aptima HPV test (Gen-Probe) detects E6/E7 mRNA of 14 oncogenic types. Its clinical performance was compared with that of the Hybrid Capture 2 DNA test (HC2; Qiagen) in women referred for colposcopy and those routinely screened. Aptima was also compared with the PreTect HPV-Proofer E6/E7 mRNA assay (Proofer; Norchip) in the referral population. Cervical specimens collected in PreservCyt (Hologic Inc.) were processed for HPV detection and genotyping with the Linear Array (LA) method (Roche Molecular Diagnostics, Laval, Quebec, Canada). Histology-confirmed high-grade cervical intraepithelial neoplasia (CIN 2) or worse (CIN 2+) served as the disease endpoint. On the basis of 1,418 referral cases (CIN 2+, n = 401), the sensitivity of Aptima was 96.3% (95% confidence interval [CI], 94.4, 98.2), whereas it was 94.3% (95% CI, 92.0, 96.6) for HC2. The specificities were 43.2% (95% CI, 40.2, 46.2) and 38.7% (95% CI, 35.7, 41.7), respectively (P < 0.05). In 1,373 women undergoing routine screening (CIN 2+, n = 7), both Aptima and HC2 showed 100% sensitivity, and the specificities were 88.3% (95% CI, 86.6, 90.0) and 85.3% (95% CI, 83.5, 87.3), respectively (P < 0.05); for women ≥ 30 years of age (n = 845), the specificities were 93.9% (95% CI, 92.3, 95.5) and 92.1% (95% CI, 90.3, 93.9), respectively (P < 0.05). On the basis of 818 referral cases (CIN 2+, n = 235), the sensitivity of Aptima was 94.9% (95% CI, 92.1, 97.7) and that of Proofer was 79.1% (95% CI, 73.9, 84.3), and the specificities were 45.8% (95% CI, 41.8, 49.8) and 75.1% (95% CI, 71.6, 78.6), respectively (P < 0.05). Both Aptima and Proofer showed a higher degree of agreement with LA genotyping than HC2. In conclusion, the Aptima test is as sensitive as HC2 but more specific for detecting CIN 2+ and can serve as a reliable test for both primary cervical cancer screening and the triage of borderline cytological abnormalities.

PubMed Disclaimer

References

    1. Anttila A., et al. 2010. Rate of cervical cancer, severe intraepithelial neoplasia, and adenocarcinoma in situ in primary HPV DNA screening with cytology triage: randomised study within organized screening programme. BMJ 340:c1804. - PMC - PubMed
    1. Bosch F. X., et al. 2008. Epidemiology and natural history of human papillomavirus infections and type-specific implications in cervical neoplasia. Vaccine 26S:K1–K16 - PubMed
    1. Bouvard V., et al. 2009. A review of human carcinogens. Part B. Biological agents. Lancet Oncol. 10:321–322 - PubMed
    1. Bulkmans N. W. J., et al. 2007. Human papillomavirus DNA testing for the detection of cervical intraepithelial neoplasia grade 3 and cancer: 5-year follow-up of a randomised controlled implementation trial. Lancet 370:1764–1772 - PubMed
    1. Castle P. E., et al. 2008. Human papillomavirus genotype specificity of Hybrid Capture 2. J. Clin. Microbiol. 46:2595–2604 - PMC - PubMed

Publication types