Personal dosimetry for interventional operators: when and how should monitoring be done?
- PMID: 21159809
- PMCID: PMC3473494
- DOI: 10.1259/bjr/24828606
Personal dosimetry for interventional operators: when and how should monitoring be done?
Abstract
Objective: Assessment of the potential doses to the hands and eyes for interventional radiologists and cardiologists can be difficult. A review of studies of doses to interventional operators reported in the literature has been undertaken.
Methods: Distributions for staff dose to relevant parts of the body per unit dose-area product and for doses per procedure in cardiology have been analysed and mean, median and quartile values derived. The possibility of using these data to provide guidance for estimation of likely dose levels is considered.
Results: Dose indicator values that could be used to predict orders of magnitude of doses to the eye, thyroid and hands from interventional operator workloads have been derived, based on the third quartile values, from the distributions of dose results analysed.
Conclusion: Dose estimates made in this way could be employed in risk assessments when reviewing protection and monitoring requirements. Data on the protection provided by different shielding and technique factors have also been reviewed to provide information for risk assessments. Recommendations on the positions in which dosemeters are worn should also be included in risk assessments, as dose measurements from suboptimal dosemeter use can be misleading.
Figures
Comment in
-
What are the implications of the proposed revision of the eye dose limit for interventional operators?Br J Radiol. 2011 Oct;84(1006):961-2. doi: 10.1259/bjr/17012242. Br J Radiol. 2011. PMID: 21933983 Free PMC article. No abstract available.
References
-
- Kim KP, Miller DL, Balter S, Kleinerman RA, Linet MS, Kwon D, et al. Occupational radiation doses to operators performing cardiac catheterization procedures. Health Phys 2008;94:211–27 - PubMed
-
- International Commission on Radiological Protection. Avoidance of radiation injuries from medical interventional procedures. ICRP Publication 85. Annals of the ICRP 30(2) 2000. - PubMed
-
- Togni M, Balmer F, Piffner D, Meier W, Zeiher AM, Meier B. Percutaneous coronary interventions in Europe 1992–2001. Eur Heart J 2004;25:1208–13 - PubMed
-
- Vaño E, González L, Beneytez F, Moreno F. Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories. Br J Radiol 1998;71:728–33 - PubMed
-
- Vano E, Gonzalez L, Fernandez JM. Eye lens exposure to radiation in interventional suites: caution is warranted. Radiology 2008;248:945–93 - PubMed