Influence of dental materials used for sealing caries lesions on laser fluorescence measurements
- PMID: 21161311
- DOI: 10.1007/s10103-010-0856-z
Influence of dental materials used for sealing caries lesions on laser fluorescence measurements
Abstract
The aim of this study was to determine the influence of thickness and aging on the intrinsic fluorescence of sealing materials and their ability to block fluorescence from the underlying surface as assessed using a laser fluorescence device. Cavities of 0.5 mm and 1 mm depth were drilled into acrylic boards which were placed over two surfaces with different fluorescence properties: a low-fluorescence surface, to assess the intrinsic fluorescence of the sealing materials, and a high-fluorescence surface, to assess the fluorescence-blocking ability of the sealing materials. Ten cavities of each depth were filled with different sealing materials: Adper Scotchbond Multi-Purpose, Adper Single Bond 2, FluroShield, Conseal f and UltraSeal XT Plus. Fluorescence was measured with a DIAGNOdent pen at five different time points: empty cavity, after polymerization, and 1 day, 1 week and 1 month after filling. The individual values after polymerization, as well as the area under the curve for the different periods were submitted to ANOVA and the Tukey test (p < 0.05). At 0.5 mm, Scotchbond, FluroShield and UltraSeal showed insignificant changes in intrinsic fluorescence with aging and lower fluorescence after polymerization than Single Bond and Conseal. At 1 mm, Scotchbond and FluroShield showed the lowest intrinsic fluorescence, but only Scotchbond showed no chagnes in fluorescence with aging. At both depths, Scotchbond blocked significantly less fluorescence. All sealing materials blocked more fluorescence when applied to a depth of 1 mm. At 0.5 mm, fissure sealants blocked more fluorescence than adhesives, and did not show significant changes with aging. Scotchbond had the least affect on the fluorescence from the underlying surface and would probably have the least affect on the monitoring of sealed dental caries by laser fluorescence.
Similar articles
-
Effect of new generation surface sealants on the marginal permeability of Class V resin composite restorations.Oper Dent. 2006 Jul-Aug;31(4):481-8. doi: 10.2341/05-77. Oper Dent. 2006. PMID: 16924989 Clinical Trial.
-
Influence of the application time on the penetration of different dental adhesives and a fissure sealant into artificial subsurface lesions in bovine enamel.Dent Mater. 2006 Jan;22(1):22-8. doi: 10.1016/j.dental.2005.03.005. Epub 2005 Jul 25. Dent Mater. 2006. PMID: 16040112
-
The use of flowable composites as filled adhesives.Dent Mater. 2002 May;18(3):227-38. doi: 10.1016/s0109-5641(01)00040-9. Dent Mater. 2002. PMID: 11823015
-
Microleakage and polymerization shrinkage of various polymer restorative materials.J Dent Child (Chic). 2008 May-Aug;75(2):125-33. J Dent Child (Chic). 2008. PMID: 18647507
-
Microtensile bond strength of total-etch and self-etching adhesives to caries-affected dentine.J Dent. 2003 Sep;31(7):469-77. doi: 10.1016/s0300-5712(03)00088-5. J Dent. 2003. PMID: 12927458
Cited by
-
Evaluation of Near-Infrared Transparent Sealants for Occlusal Sealing: An In Vitro Study.Materials (Basel). 2025 May 22;18(11):2421. doi: 10.3390/ma18112421. Materials (Basel). 2025. PMID: 40508418 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical