Pulse oximetry versus arterial blood gas specimens in long-term oxygen therapy
- PMID: 2117192
- DOI: 10.1007/BF02718208
Pulse oximetry versus arterial blood gas specimens in long-term oxygen therapy
Abstract
Portable pulse oximeters are now widely available for the assessment of arterial oxygenation, and the U.S. Medicare program considers saturation readings to be acceptable substitutes for arterial PO2 in selecting patients for long-term oxygen therapy (LTOT). Current oximeters are reasonably accurate (plus or minus 4 or 5 percent of the co-oximetry value), but the clinician should be aware of several potential problems. Readings may be inaccurate in the presence of hemodynamic instability, carboxyhemoglobinemia, jaundice, or dark skin pigmentation, and also during exercise. Indicated saturation may substantially overestimate arterial PO2 if the patient is alkalemic. Pulse oximetry cannot detect hypercapnia or acidosis. For these and other reasons, pulse oximetry should not be used in initial selection of patients for LTOT, as a substitute for arterial blood gas analysis in the evaluation of patients with undiagnosed respiratory disease, during formal cardiopulmonary exercise testing, or in the presence of an acute exacerbation. Pulse oximetry is an important addition to the clinician's armamentarium, however, for titrating the oxygen dose in stable patients, in assessing patients for desaturation during exercise, for sleep studies, and for in-home monitoring.
Similar articles
-
Assessing need for long-term oxygen therapy: a comparison of conventional evaluation and measures of ambulatory oximetry monitoring.Respir Care. 2003 Feb;48(2):115-9. Respir Care. 2003. PMID: 12556251
-
How accurate are pulse oximeters in patients with acute exacerbations of chronic obstructive airways disease?Respir Med. 2001 May;95(5):336-40. doi: 10.1053/rmed.2001.1046. Respir Med. 2001. PMID: 11392573
-
From oxygen content to pulse oximetry: completing the picture in the newborn.Acta Anaesthesiol Scand Suppl. 1995;107:95-100. doi: 10.1111/j.1399-6576.1995.tb04341.x. Acta Anaesthesiol Scand Suppl. 1995. PMID: 8599308 Review.
-
Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.Anesth Analg. 2010 Jul;111(1):143-8. doi: 10.1213/ANE.0b013e3181c91bb6. Epub 2009 Dec 10. Anesth Analg. 2010. PMID: 20007731
-
The oxygen reserve index (ORI): a new tool to monitor oxygen therapy.J Clin Monit Comput. 2018 Jun;32(3):379-389. doi: 10.1007/s10877-017-0049-4. Epub 2017 Aug 8. J Clin Monit Comput. 2018. PMID: 28791567 Free PMC article. Review.
Cited by
-
Assessment and follow up of patients prescribed long term oxygen treatment.Thorax. 1993 Jul;48(7):708-13. doi: 10.1136/thx.48.7.708. Thorax. 1993. PMID: 8153918 Free PMC article.
-
Pulse oximetry: a practical review.BMJ. 1995 Aug 5;311(7001):367-70. doi: 10.1136/bmj.311.7001.367. BMJ. 1995. PMID: 7640545 Free PMC article. Review. No abstract available.
-
SpO2/FiO2 Correlates with PaO2/FiO2 (P/F) and Radiological Biomarkers of Severity: A Retrospective Study on COVID-19 Pneumonia Patients.Biomedicines. 2025 Apr 28;13(5):1072. doi: 10.3390/biomedicines13051072. Biomedicines. 2025. PMID: 40426900 Free PMC article.
-
Arterialised earlobe blood gas analysis: an underused technique.Thorax. 1994 Apr;49(4):364-6. doi: 10.1136/thx.49.4.364. Thorax. 1994. PMID: 8202909 Free PMC article.
-
The association between forced expiratory volume in one second (FEV1) and pulse oximetric measurements of arterial oxygen saturation (SpO2) in the patients with COPD: A preliminary study.J Res Med Sci. 2014 Mar;19(3):257-61. J Res Med Sci. 2014. PMID: 24949035 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Medical