NanoDrop microvolume quantitation of nucleic acids

Affiliations

NanoDrop microvolume quantitation of nucleic acids

Philippe Desjardins et al. J Vis Exp. .

Abstract

Biomolecular assays are continually being developed that use progressively smaller amounts of material, often precluding the use of conventional cuvette-based instruments for nucleic acid quantitation for those that can perform microvolume quantitation. The NanoDrop microvolume sample retention system (Thermo Scientific NanoDrop Products) functions by combining fiber optic technology and natural surface tension properties to capture and retain minute amounts of sample independent of traditional containment apparatus such as cuvettes or capillaries. Furthermore, the system employs shorter path lengths, which result in a broad range of nucleic acid concentration measurements, essentially eliminating the need to perform dilutions. Reducing the volume of sample required for spectroscopic analysis also facilitates the inclusion of additional quality control steps throughout many molecular workflows, increasing efficiency and ultimately leading to greater confidence in downstream results. The need for high-sensitivity fluorescent analysis of limited mass has also emerged with recent experimental advances. Using the same microvolume sample retention technology, fluorescent measurements may be performed with 2 μL of material, allowing fluorescent assays volume requirements to be significantly reduced. Such microreactions of 10 μL or less are now possible using a dedicated microvolume fluorospectrometer. Two microvolume nucleic acid quantitation protocols will be demonstrated that use integrated sample retention systems as practical alternatives to traditional cuvette-based protocols. First, a direct A260 absorbance method using a microvolume spectrophotometer is described. This is followed by a demonstration of a fluorescence-based method that enables reduced-volume fluorescence reactions with a microvolume fluorospectrometer. These novel techniques enable the assessment of nucleic acid concentrations ranging from 1 pg/ μL to 15,000 ng/ μL with minimal consumption of sample.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Wilfinger WW, Mackey K, Chomczynski P. Effect of pH and Ionic Strength on the Spectrophotometric Assessment of Nucleic Acid Purity. BioTechniques. 1997;22:474–481. - PubMed
    1. Voolstra C, Jungnickel A, Borrmann L, Kirchner R, Huber A. Implen Applications Note. Munich, Germany: 2006. Spectrophotometric Quantification of Nucleic Acids: LabelGuard enables photometric quantification of submicroliter samples using a standard photometer.
    1. Jr Ingle, D J, Crouch SR. Spectrochemical analysis. Englewood Cliffs, NJ: Prentice Hall; 1988. pp. XV–590.
    1. Van Lancker M, Gheyssens LC. A comparison of four frequently used assays for quantitative determination of DNA. Anal. Lett. 1986;19:615–623.

Publication types

MeSH terms

LinkOut - more resources