Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jan;30(1):93-9.
doi: 10.7863/jum.2011.30.1.93.

Satisfactory rate of postprocessing visualization of standard fetal cardiac views from 4-dimensional cardiac volumes acquired during routine ultrasound practice by experienced sonographers in peripheral centers

Affiliations

Satisfactory rate of postprocessing visualization of standard fetal cardiac views from 4-dimensional cardiac volumes acquired during routine ultrasound practice by experienced sonographers in peripheral centers

Giuseppe Rizzo et al. J Ultrasound Med. 2011 Jan.

Abstract

The aim of this study was to evaluate the feasibility of visualizing standard cardiac views from 4-dimensional (4D) cardiac volumes obtained at ultrasound facilities with no specific experience in fetal echocardiography. Five sonographers prospectively recorded 4D cardiac volumes starting from the 4-chamber view on 500 consecutive pregnancies at 19 to 24 weeks' gestation undergoing routine ultrasound examinations (100 pregnancies for each sonographer). Volumes were sent to the referral center, and 2 independent reviewers with experience in 4D fetal echocardiography assessed their quality in the display of the abdominal view, 4-chamber view, left and right ventricular outflow tracts, and 3-vessel and trachea view. Cardiac volumes were acquired in 474 of 500 pregnancies (94.8%). The 2 reviewers respectively acknowledged the presence of satisfactory images in 92.4% and 93.6% of abdominal views, 91.5% and 93.0% of 4-chamber views, in 85.0% and 86.2% of left ventricular outflow tracts, 83.9% and 84.5% of right ventricular outflow tracts, and 85.2% and 84.5% of 3-vessel and trachea views. The presence of a maternal body mass index of greater than 30 altered the probability of achieving satisfactory cardiac views, whereas previous maternal lower abdominal surgery did not affect the quality of reconstructed cardiac views. In conclusion, cardiac volumes acquired by 4D sonography in peripheral centers showed high enough quality to allow satisfactory diagnostic cardiac views.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources