Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Apr;32(4):426-32.
doi: 10.1007/s00246-010-9873-8. Epub 2011 Jan 6.

Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease

Affiliations
Comparative Study

Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease

Faris Al-Mousily et al. Pediatr Cardiol. 2011 Apr.

Abstract

Pediatric patients with complex congenital heart disease (CHD) face a lifetime of treatment with interventional therapeutic and palliative procedures. Echocardiography remains the mainstay for noninvasive imaging of congenital heart lesions. This often is supplemented with diagnostic cardiac catheterization for additional anatomic and physiologic characterization. However, recent technological improvements in computed tomography (CT) and magnetic resonance imaging (MRI) have led to an increased focus on the use of these techniques given their better safety profile. This study aimed to review the authors' experience with a 320-slice multidetector CT scanner in the evaluation of CHD in children. This retrospective case study investigated 22 infants and young children with a provisional diagnosis of CHD. Their anatomic evaluation was performed using a 320-slice Aquilon ONE CT scanner. Of these 22 patients, 14 were examined without cardiac gating. This was subsequently modified to a prospective gated, targeted protocol to decrease the radiation dose. The images were interpreted by an experienced radiologist and a pediatric cardiologist. Continuous variables were expressed as mean and standard deviation or range, and the two imaging protocols were compared. A comparison of exposure rates with those from other pediatric studies that had used the 64-slice CT angiography also was performed. For the first group of patients, with nongated CT examinations, the mean effective whole-body radiation dose was 1.8 ± 0.71 millisieverts (mSv) (range, 0.96-3.2 mSv). For the second group, the mean was 0.8 ± 0.39 mSv (range, 0.4-1.5 mSv). Although the radiation dose was reduced dramatically, clinicians must be vigilant about the cumulative risk of radiation exposure.

PubMed Disclaimer

References

    1. Radiology. 2004 Aug;232(2):347-53 - PubMed
    1. Cardiol Young. 2005 Feb;15(1):47-51 - PubMed
    1. Heart. 2010 Feb;96(4):269-74 - PubMed
    1. Pediatr Radiol. 2006 Sep;36 Suppl 2:154-8 - PubMed
    1. AJR Am J Roentgenol. 2008 May;190(5):1232-40 - PubMed

Publication types