[Efficacy and delivery outcomes of women underwent double-catheter epidural block during labor]
- PMID: 21211279
[Efficacy and delivery outcomes of women underwent double-catheter epidural block during labor]
Abstract
Objective: To investigate the efficacy and pregnancy outcomes of women receiving double-catheter epidural block in labor analgesia, and compare the results with single-catheter epidural block.
Methods: A double-blind clinical trial was conducted on 206 full-term singleton primiparas, aged 25 - 35 and at the 37 - 42 weeks of gestation who delivered at the Department of Obstetrics, Qingdao Municipal Hospital from August 2006 to December 2008, which were randomly divided into two groups: double-catheter epidural block (group D, n = 103) and single-catheter epidural-block (group S, n = 103). Women in group D were given mixture of 0.1% repivacaine hydrochloride and 0.5 mg/L sufentinil 4 - 6 ml as initial dose. Patient control epidural analgesia pump (PCEA) was connected with the upper catheter after 45 minutes. A bolus dose of 4 - 6 ml analgesia mixture was infused according to the condition through the lower catheter. Women in group S received analgesia mixture 10 - 15 ml as initial dose and PCEA pump was connected after 45 minutes. Oxytocin was infused in both groups according to uterine contraction after 30 minutes. The following indexes was observed: (1) visual analogue scales (VAS); (2)modified Bromage Scores; (3) the total dose of analgesia mixture, the percentage of oxytocin infusion, duration of labor and duration of the second stage of labor; (4) fetal birth weight and Apgar scores (1, 5 minutes); (5) mode of delivery; (6) the concentration of plasma cortisol and angiotension II at the beginning of regular uterine contraction and at the time when cervical dilated to 4 cm and 10 cm and fetal disengagement; (7) anesthesia-related complications.
Results: (1) The neonatal birth weight and Apgar scores (1, 5 minutes) of group D were (3456 ± 468) g, 9.8 ± 0.6 and 9.9 ± 0.7, respectively, while (3399 ± 569) g, 9.8 ± 0.5 and 9.9 ± 0.7 in group S (P > 0.05). No motor function block was reported in any group and the modified Bromage score was zero. (2) The total dose of analgesia mixture in group D was similar to that in group S [(57 ± 9) ml vs. (58 ± 11) ml, P > 0.05]. However, the percentage of women received oxytocin in group D was smaller [59.2% (61/103) vs. 81.6% (84/103), P < 0.01], and the total time of labor and the duration of second stage of labor in group D were shorter [(532 ± 140) minutes vs. (608 ± 150) minutes; (46 ± 31) minutes vs. (60 ± 34) minutes, P < 0.05]. (3) There were no significant differences in VAS at 30 minutes after initial dose and in the first stage of labor between group D and S (1.2 ± 1.1 vs 1.2 ± 1.1, 1.1 ± 1.1 vs. 1.2 ± 1.0, P > 0.05). VAS at the second stage of labor stage was lower in group D than in group S (1.2 ± 1.1 vs. 4.5 ± 2.2, P < 0.01). (4) The rate of cesarean section, instrumental delivery and episiotomy in group D were lower than in group S (7.8% vs. 17.5%, 7.8% vs. 15.5%, 10.7% vs. 18.4%, P < 0.05). The incidence of fetal distress and meconium-stained amniotic fluid as the indication of cesarean section were similar between the two groups (P > 0.05). Lower incidence of fetal malpresentation and arrested second stage of labor were shown in group D than in group S (2.9% vs. 9.7%, 1.0% vs. 5.8%, P < 0.05). (5) The concentration of plasma cortisol and angiotension II were lower in group D than in group S [(86 ± 25) ng/L vs. (100 ± 20) ng/L, (278 ± 53) nmol/L vs. (311 ± 53) nmol/L, P < 0.05] only at the end of second stage of labor, but not at any other times (P > 0.05). (6) No serious anesthesia-related complications were reported in any groups. Some light backache around the puncture point were complained by 29.1% (30/103) of the women in group D and 31.1% (32/103) in group S (P > 0.05).
Conclusion: Double-catheter epidural block can provide better analgesia effect during labor than single-catheter epidural block, without any adverse influence on delivery outcomes.
Similar articles
-
Programmed intermittent epidural bolus versus continuous epidural infusion for labor analgesia: the effects on maternal motor function and labor outcome. A randomized double-blind study in nulliparous women.Anesth Analg. 2011 Oct;113(4):826-31. doi: 10.1213/ANE.0b013e31822827b8. Epub 2011 Jul 25. Anesth Analg. 2011. PMID: 21788309 Clinical Trial.
-
[Effects of double-catheter epidural analgesia by lidocaine injection respectively on the delivery outcomes and maternal-infant complications for persistent posterior or lateral occipital position of protracted active phase].Zhonghua Fu Chan Ke Za Zhi. 2020 Jul 25;55(7):457-464. doi: 10.3760/cma.j.cn112141-20191228-00705. Zhonghua Fu Chan Ke Za Zhi. 2020. PMID: 32842249 Clinical Trial. Chinese.
-
Does epidural versus combined spinal-epidural analgesia prolong labor and increase the risk of instrumental and cesarean delivery in nulliparous women?J Clin Anesth. 2009 Mar;21(2):94-7. doi: 10.1016/j.jclinane.2008.06.020. J Clin Anesth. 2009. PMID: 19329011
-
Sufentanil versus fentanyl for pain relief in labor involving combined spinal-epidural analgesia: a systematic review and meta-analysis of randomized controlled trials.Eur J Clin Pharmacol. 2020 Apr;76(4):501-506. doi: 10.1007/s00228-019-02806-x. Epub 2020 Jan 7. Eur J Clin Pharmacol. 2020. PMID: 31912188
-
Epidural analgesia-anaesthesia in obstetrics.Eur J Anaesthesiol. 2000 Sep;17(9):542-58. doi: 10.1046/j.1365-2346.2000.00733.x. Eur J Anaesthesiol. 2000. PMID: 11029122 Review.
Cited by
-
Dual epidural catheters for labor analgesia in a spinal cord injury patient: a case report.Braz J Anesthesiol. 2023 Jul-Aug;73(4):506-509. doi: 10.1016/j.bjane.2022.03.001. Epub 2022 Mar 14. Braz J Anesthesiol. 2023. PMID: 35296426 Free PMC article.
-
Effects of Labor Epidural Analgesia on Short Term Neonatal Morbidity.Int J Womens Health. 2020 Feb 4;12:59-70. doi: 10.2147/IJWH.S228738. eCollection 2020. Int J Womens Health. 2020. PMID: 32099485 Free PMC article.
-
Neonatal Outcomes of Term Infants Born with Meconium-Stained Amniotic Fluid.Children (Basel). 2023 Apr 26;10(5):780. doi: 10.3390/children10050780. Children (Basel). 2023. PMID: 37238328 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous