Randomized Controlled Trial
. 2011 Jan 11;57(2):167-72.
doi: 10.1016/j.jacc.2010.08.624.

Device-detected atrial tachyarrhythmias predict adverse outcome in real-world patients with implantable biventricular defibrillators

Affiliations
Free article
Randomized Controlled Trial

Device-detected atrial tachyarrhythmias predict adverse outcome in real-world patients with implantable biventricular defibrillators

Massimo Santini et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: The purpose of this analysis was to evaluate the correlation between atrial tachycardia (AT) or atrial fibrillation (AF) and clinical outcomes in heart failure (HF) patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D).

Background: In HF patients, AT and AF have high prevalence and are associated with compromised hemodynamic function.

Methods: Forty-four Italian cardiological centers followed up 1,193 patients who received a CRT-D according to current guidelines for advanced HF, New York Heart Association functional class ≥ II, left ventricular ejection fraction ≤ 35%, and QRS complex ≥ 120 ms. All patients were in sinus rhythm at implant.

Results: During a median follow-up period of 13 months, AT/AF >10 min occurred in 361 of 1,193 (30%) patients. The composite end point (deaths or HF hospitalizations) occurred in 174 of 1,193 (14.6%). Multivariate time-dependent Cox regression analyses showed that composite end point risk was higher among patients with device-detected AT/AF (hazard ratio [HR]: 2.16, p = 0.032), New York Heart Association functional class III or IV compared with II (HR: 2.09, p = 0.002), and absence of beta-blockers (HR: 1.36, p = 0.036). Furthermore, the composite end point risk was inversely associated with left ventricular ejection fraction (HR: 1.04, p = 0.045), increasing by a factor of 4% for each 1% decrease in left ventricular ejection fraction.

Conclusions: In HF patients with CRT-D, device-detected AT/AF is associated with a worse prognosis. Continuous device diagnostics monitoring and Web-based alerts may inform the physician of AT/AF occurrences and identify patients at risk of cardiac deterioration or patients with suboptimal rate or rhythm control. (Italian ClinicalService Project; NCT01007474).