Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1977 Oct;70(4):507-30.
doi: 10.1085/jgp.70.4.507.

Liquid and solid-state Cl- -sensitive microelectrodes. Characteristics and application to intracellular Cl- activity in Balanus photoreceptor

Comparative Study

Liquid and solid-state Cl- -sensitive microelectrodes. Characteristics and application to intracellular Cl- activity in Balanus photoreceptor

J H Saunders et al. J Gen Physiol. 1977 Oct.

Abstract

When intracellular chloride activity (aiCl) was monitored with chloride-sensitive liquid ion exchanges (CLIX) microelectrodes in Balanus photoreceptors, replacement of extracellular chloride (Cl0) by methanesulfonate or glutamate was followed by a rapid but incomplete loss of aiCl. When propionate was used as the extracellular anion substitute, CLIX electrodes detected an apparent gain in aiCl, while a newly designed Ag-AgCl wire-in glass microelectrode showed a loss of aiCl under the same conditions. This discrepancy in Cl- washout when propionate replaced Cl0 is explained by the differences in selectivity of CLIX and Ag-AgCl electrodes for native intracellular anions and for the extracellular anion substitute which also replaces Cli and interferes in the determination of aiCl. Both electrodes indicate that ECl approximately Em when the cells are bathed in normal barnacle saline, and both electrodes showed the rate of Cl washout (tau approximately 5 min) to be independent of Cli when Cl0 was replaced by glutamate. Details of Ag-AgCl microelectrode construction are presented. These electrodes were tested and found to be insensitive to the organic anion substitutes used in this study. Selectivity data of CLIX electrodes for several anions of biological interest are described.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann N Y Acad Sci. 1968 Feb 1;148(1):36-53 - PubMed
    1. J Gen Physiol. 1969 Jul;54(1):33-52 - PubMed
    1. J Physiol. 1970 Jun;208(2):385-413 - PubMed
    1. J Gen Physiol. 1971 Apr;57(4):408-34 - PubMed
    1. J Gen Physiol. 1972 Nov;60(5):499-518 - PubMed

Publication types