Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools
- PMID: 2123116
- PMCID: PMC1035263
- DOI: 10.1136/oem.47.11.733
Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools
Abstract
Possible relations between incidence and prevalence of sick building syndrome (SBS), indoor exposures, and personal factors were studied in a four year longitudinal study among personnel (n = 129) in six primary schools. The mean concentration of carbon dioxide was above the recommended value of 0.08 microliter/l (800 ppm) in all schools, indicating a poor outdoor air supply. Indoor concentration of volatile hydrocarbon (VOC) was enhanced at high room temperatures. Respirable dust, but not concentration of VOC was enhanced at lower ventilation rates and high air humidity. Chronic SBS was related to VOC, previous wall to wall carpeting in the schools, hyper-reactivity, and psychosocial factors. Incidence of new SBS was related to concentration of respirable dust, current smoking, and the psychosocial climate. Remission of hyperreactivity, decrease in sick leave owing to airway illness, removal of carpeting in the schools, and moving from new to old dwellings resulted in a decrease in SBS score. It is concluded that SBS is of multifactorial origin, related to a variety of factors and exposures. The total concentration of hydrocarbons is a simple and convenient measure of exposure, which also seems to be a predictor of chronic symptoms. Further investigations on the effect of temperature, ventilation, and air humidity on SBS should consider how these factors may influence the chemical composition of the air. Because poor air quality in schools could also affect the children, it may have implications for the state of health of a large proportion of the population.
Similar articles
-
The prevalence and incidence of sick building syndrome in Chinese pupils in relation to the school environment: a two-year follow-up study.Indoor Air. 2011 Dec;21(6):462-71. doi: 10.1111/j.1600-0668.2011.00726.x. Epub 2011 Jun 16. Indoor Air. 2011. PMID: 21615503
-
Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.Occup Environ Med. 1995 Jun;52(6):388-95. doi: 10.1136/oem.52.6.388. Occup Environ Med. 1995. PMID: 7627316 Free PMC article.
-
Indoor air quality and personal factors related to the sick building syndrome.Scand J Work Environ Health. 1990 Apr;16(2):121-8. doi: 10.5271/sjweh.1808. Scand J Work Environ Health. 1990. PMID: 2353195
-
Ventilation and health in non-industrial indoor environments: report from a European multidisciplinary scientific consensus meeting (EUROVEN).Indoor Air. 2002 Jun;12(2):113-28. doi: 10.1034/j.1600-0668.2002.01145.x. Indoor Air. 2002. PMID: 12216467 Review.
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
Cited by
-
Indoor air concentration of chlordane, and its seasonal variation.Bull Environ Contam Toxicol. 1994 Apr;52(4):546-53. doi: 10.1007/BF00194142. Bull Environ Contam Toxicol. 1994. PMID: 8167448 No abstract available.
-
Evaluating prevalence and risk factors of building-related symptoms among office workers: Seasonal characteristics of symptoms and psychosocial and physical environmental factors.Environ Health Prev Med. 2017 Apr 12;22(1):38. doi: 10.1186/s12199-017-0645-4. Environ Health Prev Med. 2017. PMID: 29165170 Free PMC article.
-
Relationship between sick building syndrome and indoor air quality among hospital staff.Med Lav. 2018 Dec 20;109(6):435-443. doi: 10.23749/mdl.v110i6.7628. Med Lav. 2018. PMID: 30556534 Free PMC article.
-
Atopy, symptoms and indoor environmental perceptions, tear film stability, nasal patency and lavage biomarkers in university staff.Int Arch Occup Environ Health. 2008 Jul;81(7):861-72. doi: 10.1007/s00420-007-0280-2. Epub 2007 Dec 8. Int Arch Occup Environ Health. 2008. PMID: 18066577
-
Occupant health in buildings: Impact of the COVID-19 pandemic on the opinions of building professionals and implications on research.Build Environ. 2022 Jan;207:108440. doi: 10.1016/j.buildenv.2021.108440. Epub 2021 Oct 16. Build Environ. 2022. PMID: 34697517 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical