Power estimation for multireader ROC methods an updated and unified approach
- PMID: 21232681
- PMCID: PMC3053069
- DOI: 10.1016/j.acra.2010.09.007
Power estimation for multireader ROC methods an updated and unified approach
Erratum in
- Acad Radiol. 2013 May;20(5):659-60
Abstract
Rationale and objectives: We describe a step-by-step procedure for estimating power and sample size for planned multireader receiver operating characteristic (ROC) studies that will be analyzed using either the Dorfman-Berbaum-Metz (DBM) or Obuchowski-Rockette (OR) method. This procedure updates previous approaches by incorporating recent methodological developments and unifies the approaches by allowing inputs to be conjectured parameter values or outputs from either a DBM or OR pilot-study analysis.
Materials and methods: Power computations are described in a step-by-step procedure and the theoretical basis for the procedure is described. Updates include using the currently recommended denominator degrees of freedom, accounting for different pilot and planned study normal-to-abnormal case ratios, and a new method for computing the OR test-by-reader variance component.
Results: Using a real dataset we illustrate how to compute the power for two planned studies, one having the same normal-to-abnormal case ratio as the pilot study and the other having a different ratio. In a simulation study, we show that the proposed procedure gives mean power estimates close to the true power.
Conclusions: Application of the updated procedure is straightforward. It is important that pilot data be comparable to the planned study with respect to the modalities, reader expertise, and case selection. Variability of the power estimates warrants further investigation.
Published by Elsevier Inc.
Comment in
-
How many readers and cases does one need to conduct an ROC study?Acad Radiol. 2011 Feb;18(2):127-8. doi: 10.1016/j.acra.2010.12.003. Acad Radiol. 2011. PMID: 21232680 No abstract available.
References
-
- Dorfman DD, Berbaum KS, Metz CE. Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method. Investigative Radiology. 1992;27:723–731. - PubMed
-
- Dorfman DD, Berbaum KS, Lenth RV, Chen YF, Donaghy BA. Monte Carlo validation of a multireader method for receiver operating characteristic discrete rating data: factorial experimental design. Academic Radiology. 1998;5:591–602. - PubMed
-
- Obuchowski NA, Rockette HE. Hypothesis testing of the diagnostic accuracy for multiple diagnostic tests: an ANOVA approach with dependent observations. Communications in Statistics: Simulation and Computation. 1995;24:285–308.
-
- Obuchowski NA. Multi-reader multi-modality ROC studies: hypothesis testing and sample size estimation using an ANOVA approach with dependent observations. With rejoinder. Academic Radiology. 1995;2(Suppl 1):S22–S29. - PubMed
-
- Obuchowski NA, McClish DK. Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Statistics in Medicine. 1997;16:1529–1542. - PubMed