The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement
- PMID: 21236431
- DOI: 10.1016/j.jbiomech.2010.11.026
The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement
Abstract
Periprosthetic bone resorption after tibial prosthesis implantation remains a concern for long-term fixation performance. The fixation techniques may inherently aggravate the "stress-shielding" effect of the implant, leading to weakened bone foundation. In this study, two cemented tibial fixation cases (fully cemented and hybrid cementing with cement applied under the tibial tray leaving the stem uncemented) and three cementless cases relying on bony ingrowth (no, partial and fully ingrown) were modelled using the finite element method with a strain-adaptive remodelling theory incorporated to predict the change in the bone apparent density after prosthesis implantation. When the models were loaded with physiological knee joint loads, the predicted patterns of bone resorption correlated well with reported densitometry results. The modelling results showed that the firm anchorage fixation formed between the prosthesis and the bone for the fully cemented and fully ingrown cases greatly increased the amount of proximal bone resorption. Bone resorption in tibial fixations with a less secure anchorage (hybrid cementing, partial and no ingrowth) occurred at almost half the rate of the changes around the fixations with a firm anchorage. The results suggested that the hybrid cementing fixation or the cementless fixation with partial bony ingrowth (into the porous-coated prosthesis surface) is preferred for preserving proximal tibial bone stock, which should help to maintain post-operative fixation stability. Specifically, the hybrid cementing fixation induced the least amount of bone resorption.
Copyright © 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions.J Biomech. 2010 Apr 19;43(6):1074-80. doi: 10.1016/j.jbiomech.2009.12.006. Epub 2010 Mar 1. J Biomech. 2010. PMID: 20189576
-
Tibial component fixation with cement: full- versus surface-cementation techniques.Clin Orthop Relat Res. 2003 Apr;(409):158-68. doi: 10.1097/01.blo.0000058638.94987.20. Clin Orthop Relat Res. 2003. PMID: 12671498
-
Cementing the tibial component in total knee arthroplasty: which technique is the best?J Arthroplasty. 2011 Apr;26(3):492-6. doi: 10.1016/j.arth.2010.01.107. Epub 2010 Apr 8. J Arthroplasty. 2011. PMID: 20381290
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
The role of the cemented all-polyethylene tibial component in total knee replacement: a 30-year patient follow-up and review of the literature.Knee. 2010 Dec;17(6):412-6. doi: 10.1016/j.knee.2009.11.008. Epub 2010 Jan 8. Knee. 2010. PMID: 20060725 Review.
Cited by
-
Clinical Outcomes of Tibial Components with Modular Stems Used in Primary TKA.Adv Orthop. 2014;2014:651279. doi: 10.1155/2014/651279. Epub 2014 Feb 5. Adv Orthop. 2014. PMID: 24669319 Free PMC article.
-
Outcomes of a newer-generation cementless total knee arthroplasty design in patients less than 50 years of age.Ann Transl Med. 2017 Dec;5(Suppl 3):S24. doi: 10.21037/atm.2017.08.20. Ann Transl Med. 2017. PMID: 29299471 Free PMC article.
-
Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems.PLoS One. 2017 Sep 8;12(9):e0184361. doi: 10.1371/journal.pone.0184361. eCollection 2017. PLoS One. 2017. PMID: 28886100 Free PMC article.
-
Mobile-bearing total knee arthroplasty implants combined with surface cementation produced satisfactory clinical and radiographic outcomes at the 5-year follow-up.Knee Surg Sports Traumatol Arthrosc. 2019 Jul;27(7):2181-2188. doi: 10.1007/s00167-019-05512-4. Epub 2019 Apr 23. Knee Surg Sports Traumatol Arthrosc. 2019. PMID: 31016360
-
Simulation on the internal structure of three-dimensional proximal tibia under different mechanical environments.Biomed Eng Online. 2013 Dec 20;12:130. doi: 10.1186/1475-925X-12-130. Biomed Eng Online. 2013. PMID: 24359345 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical