Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study
- PMID: 21237569
- DOI: 10.1016/j.pain.2010.11.013
Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study
Abstract
Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, P<.05); the difference in variance amounted to 5%. There were no differences between study centres. In a subgroup with an unaffected control area (n=43), reliabilities were significantly better in the test area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each P<.01), suggesting that disease-related systematic variance enhances reliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non-neuropathic pain.
Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Comment in
-
Good from far. Far from good.Pain. 2013 Jan;154(1):175-176. doi: 10.1016/j.pain.2012.10.011. Epub 2012 Oct 24. Pain. 2013. PMID: 23182625 No abstract available.
-
Response to letter by Werner et al.Pain. 2013 Jan;154(1):176-178. doi: 10.1016/j.pain.2012.10.012. Epub 2012 Oct 24. Pain. 2013. PMID: 23206973 No abstract available.
References
-
- Anderson TW. R.A. Fisher and multivariate analysis. Stat Sci. 1996;11:20-34.
-
- Antonaci F, Sand T, Lucas GA. Pressure algometry in healthy subjects: inter-examiner variability. Scand J Rehabil Med. 1998;30:3-8.
-
- Arezzo J, Bolton C, Boulton A, Casey K, Dyck P, Cornblath D, Fields H, Hansson P, Greenspan J, Harati Y, Jamal G, Kennedy W, Kenshalo D, Light A, Lindblom U, O’Brien P, Ochoa J, Zimmermann I. Quantitative sensory testing: a consensus report from the Peripheral Neuropathy Association. Neurology. 1993;43:1050-1052.
-
- Arezzo JC, Schaumburg HH, Laudadio C. Thermal sensitivity tester. Device for quantitative assessment of thermal sense in diabetic neuropathy. Diabetes. 1986;35:590-592.
-
- Backonja MM, Walk D, Edwards RR, Sehgal N, Moeller-Bertram T, Wasan A, Irving G, Argoff C, Wallace M. Quantitative sensory testing in measurement of neuropathic pain phenomena and other sensory abnormalities. Clin J Pain. 2009;25:641-647.