Automated planning of tangential breast intensity-modulated radiotherapy using heuristic optimization
- PMID: 21237584
- DOI: 10.1016/j.ijrobp.2010.11.016
Automated planning of tangential breast intensity-modulated radiotherapy using heuristic optimization
Abstract
Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning.
Method and materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle(3)) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume.
Results: The mean time to generate a complete treatment plan was 6 min, 50 s ± 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses.
Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical practice.
Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Automation and intensity modulated radiation therapy for individualized high-quality tangent breast treatment plans.Int J Radiat Oncol Biol Phys. 2014 Nov 1;90(3):688-95. doi: 10.1016/j.ijrobp.2014.06.056. Epub 2014 Aug 23. Int J Radiat Oncol Biol Phys. 2014. PMID: 25160607
-
Flattening filter free vs flattened beams for breast irradiation.Int J Radiat Oncol Biol Phys. 2013 Feb 1;85(2):506-13. doi: 10.1016/j.ijrobp.2012.03.040. Epub 2012 Jun 5. Int J Radiat Oncol Biol Phys. 2013. PMID: 22672750
-
Planning hybrid intensity modulated radiation therapy for whole-breast irradiation.Int J Radiat Oncol Biol Phys. 2012 Sep 1;84(1):e115-22. doi: 10.1016/j.ijrobp.2012.02.025. Epub 2012 Apr 27. Int J Radiat Oncol Biol Phys. 2012. PMID: 22543199
-
Intensity-modulated radiotherapy of the female breast.Med Dosim. 2002 Summer;27(2):79-90. doi: 10.1016/s0958-3947(02)00089-4. Med Dosim. 2002. PMID: 12074472 Review.
-
Intensity-modulated radiotherapy for breast cancer: advances in whole and partial breast treatment.Front Radiat Ther Oncol. 2011;43:292-314. doi: 10.1159/000322461. Epub 2011 May 20. Front Radiat Ther Oncol. 2011. PMID: 21625159 Review.
Cited by
-
Goal-Driven Beam Setting Optimization for Whole-Breast Radiation Therapy.Technol Cancer Res Treat. 2019 Jan 1;18:1533033819858661. doi: 10.1177/1533033819858661. Technol Cancer Res Treat. 2019. PMID: 31242822 Free PMC article.
-
Evaluation of a new commercial automated planning software for tangential breast intensity-modulated radiation therapy.Radiol Phys Technol. 2019 Sep;12(3):249-259. doi: 10.1007/s12194-019-00515-9. Epub 2019 May 21. Radiol Phys Technol. 2019. PMID: 31115835
-
Reduction of heart and lung normal tissue complication probability using automatic beam angle optimization and more generic optimization objectives for breast radiotherapy.Phys Imaging Radiat Oncol. 2021 Apr 28;18:48-50. doi: 10.1016/j.phro.2021.04.002. eCollection 2021 Apr. Phys Imaging Radiat Oncol. 2021. PMID: 34258407 Free PMC article.
-
Relationship Between Dose and Local Control in Five-fraction Stereotactic Body Radiotherapy for Hepatocellular Carcinoma.In Vivo. 2025 Sep-Oct;39(5):2898-2907. doi: 10.21873/invivo.14090. In Vivo. 2025. PMID: 40877183 Free PMC article.
-
Automated IMRT planning with regional optimization using planning scripts.J Appl Clin Med Phys. 2013 Jan 7;14(1):4052. doi: 10.1120/jacmp.v14i1.4052. J Appl Clin Med Phys. 2013. PMID: 23318393 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical