Multicenter Study
. 2011 Mar;66(3):213-9.
doi: 10.1136/thx.2010.152801. Epub 2011 Jan 20.

A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care

Affiliations
Multicenter Study

A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care

Ching Li Chai-Coetzer et al. Thorax. 2011 Mar.

Abstract

Background: To address the growing burden of disease and long waiting lists for sleep services, a simplified two-stage model was developed and validated for identifying obstructive sleep apnoea (OSA) in primary care using a screening questionnaire followed by home sleep monitoring.

Methods: 157 patients aged 25-70 years attending their primary care physician for any reason at six primary care clinics in rural and metropolitan regions of South Australia participated. The first 79 patients formed the development group and the next 78 patients the validation group. A screening questionnaire was developed from factors identified from sleep surveys, demographic and anthropometric data to be predictive of moderate to severe OSA. Receiver operating characteristic (ROC) curve analysis was used to validate the two-channel ApneaLink device against full polysomnography. The diagnostic accuracy of the overall two-stage model was then evaluated.

Results: Snoring, waist circumference, witnessed apnoeas and age were predictive of OSA and incorporated into a screening questionnaire (ROC area under curve (AUC) 0.84, 95% CI 0.75 to 0.94, p<0.001). ApneaLink oximetry with a 3% dip rate was highly predictive of OSA (AUC 0.96, 95% CI 0.91 to 1.0, p<0.001). The two-stage diagnostic model showed a sensitivity of 0.97 (95% CI 0.81 to 1.00) and specificity of 0.87 (95% CI 0.74 to 0.95) in the development group, and a sensitivity of 0.88 (95% CI 0.60 to 0.98) and specificity of 0.82 (95% CI 0.70 to 0.90) in the validation group.

Conclusion: A two-stage model of screening questionnaire followed by home oximetry can accurately identify patients with OSA in primary care and has the potential to expedite care for patients with this common sleep disorder.

PubMed Disclaimer

Publication types