Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Jan;17(1):53-9.
doi: 10.1002/lt.22186.

Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation

Affiliations
Free article
Comparative Study

Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation

Young Hee Shin et al. Liver Transpl. 2011 Jan.
Free article

Abstract

We evaluated the value of the stroke volume variation (SVV) calculated with the Vigileo monitor, which recently has been increasingly advocated for fluid management, as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation (LT). We also compared SVV to the central venous pressure (CVP) and pulmonary arterial occlusion pressure (PAOP) in patients. Thirty-three adult recipients scheduled for elective living donor LT were enrolled in this study. Twenty minutes after the start of the anhepatic phase, the CVP, PAOP, approximate inferior vena caval pressure, femoral SVV, and cardiac output values were measured before and 12 minutes after fluid loading. Fluid loading was performed with a 6% hydroxyethyl starch solution (10 mL/kg). The responders were defined as patients whose cardiac index increased ≥ 15% after fluid loading. Receiver operating characteristic (ROC) analysis showed that only femoral SVV (area under the curve = 0.894, P = 0.0001) could be used to predict fluid responsiveness during the anhepatic phase of LT. The area under the ROC curve for femoral SVV was 0.894 (P = 0.0001), and it was significantly larger than those for CVP (area under the curve = 0.576, P = 0.004) and PAOP (area under the curve = 0.670, P = 0.021). Femoral SVV >8% identified the responders with a sensitivity of 89% and a specificity of 80%. Our results suggest that femoral SVV derived with the Vigileo monitor would be useful for fluid management during the anhepatic phase in LT recipients.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources