Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jun 1;56(3):1316-28.
doi: 10.1016/j.neuroimage.2011.01.020. Epub 2011 Jan 19.

Quantification of light reflectance spectroscopy and its application: determination of hemodynamics on the rat spinal cord and brain induced by electrical stimulation

Affiliations

Quantification of light reflectance spectroscopy and its application: determination of hemodynamics on the rat spinal cord and brain induced by electrical stimulation

Vikrant Sharma et al. Neuroimage. .

Abstract

Two quantification methods for light reflectance spectroscopy (LRS) were developed and validated to determine absolute and relative values of hemodynamic parameters and light scattering, followed by a specific application using in vivo animal experiments. A single-channel LRS system consisted of a light source, CCD-array detector, and a computer along with a bifurcated, 2-mm-diameter optical probe; this system was utilized to perform laboratory tissue phantoms for validation of the algorithms. In the animal study, a multi-channel, multisite approach was used to measure several reflectance spectra from rat brain and spinal cord on both the ipsi-lateral and contra-lateral sides, using thin 800-μm-diameter optic probes. The neuro-hemodynamic changes were induced by 10-V electrical stimulation in rat hind paw. The LRS data of the animals were analyzed using both absolute and relative methods. The results show that the relative method is computation-efficient and offers a quick estimation of changes in oxy-hemoglobin concentration for real-time monitoring. The absolute quantification method, on the other hand, provides us with an accurate computational tool to calculate absolute values of oxy-, deoxy-, total hemoglobin concentrations, and light scattering coefficients. We also observe that the hemodynamic responses in rat spinal cord were delayed with a few seconds and have an overall broader full width at half maximum, as compared to those from rat somatosensory cortex. LRS as a measurement system provides a robust method for studying local hemodynamic changes and a potential technique to investigate hemo-neural mechanisms in pain processing.

PubMed Disclaimer

MeSH terms

LinkOut - more resources