Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2011 Mar;37(3):525-31.
doi: 10.1016/j.jcrs.2010.10.044. Epub 2011 Jan 22.

Reading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: Two-year follow-up

Affiliations
Clinical Trial

Reading performance after implantation of a small-aperture corneal inlay for the surgical correction of presbyopia: Two-year follow-up

Alois K Dexl et al. J Cataract Refract Surg. 2011 Mar.

Abstract

Purpose: To evaluate the change in reading-performance parameters after implantation of the Kamra small-aperture intracorneal inlay over a 2-year follow-up.

Setting: University Eye Clinic, Paracelsus Medical University, Salzburg, Austria.

Design: Cohort study.

Methods: This study comprised naturally emmetropic presbyopic patients. Bilateral reading acuity, reading distance, reading speed, and the smallest log-scaled sentence were evaluated in a standardized testing procedure using the Salzburg Reading Desk. The minimum postoperative follow-up was 24 months.

Results: The study enrolled 32 patients. The reading desk results showed a significant improvement in each parameter tested. After a mean follow-up of 24.2 months ± 0.8 (SD), the mean reading distance changed from the preoperative value of 48.1 ± 5.5 cm to 38.9 ± 6.3 cm (P < .0001), the mean reading acuity at best distance improved from 0.3 ± 0.14 logRAD to 0.24 ± 0.11 logRAD (P < .000001), and the mean reading speed increased from 142 ± 13 words per minute (wpm) to 149 ± 17 wpm (P=.029). One patient lost 1 line, and 1 patient had no change. The improvement was up to 6 log-scaled lines (mean improvement 2.7 ± 1.6 lines) in the other 30 patients.

Conclusions: After implantation of the small-aperture intracorneal inlay, there was an improvement in all tested reading performance parameters in emmetropic presbyopic patients; the improvement was the result of an increased depth of field. These 2-year results indicate that the inlay is an effective treatment for presbyopia.

PubMed Disclaimer