Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Mar;34(3):533-9.
doi: 10.2337/dc10-1259. Epub 2011 Jan 25.

The Diabeo software enabling individualized insulin dose adjustments combined with telemedicine support improves HbA1c in poorly controlled type 1 diabetic patients: a 6-month, randomized, open-label, parallel-group, multicenter trial (TeleDiab 1 Study)

Collaborators, Affiliations
Randomized Controlled Trial

The Diabeo software enabling individualized insulin dose adjustments combined with telemedicine support improves HbA1c in poorly controlled type 1 diabetic patients: a 6-month, randomized, open-label, parallel-group, multicenter trial (TeleDiab 1 Study)

Guillaume Charpentier et al. Diabetes Care. 2011 Mar.

Abstract

Objective: To demonstrate that Diabeo software enabling individualized insulin dose adjustments combined with telemedicine support significantly improves HbA(1c) in poorly controlled type 1 diabetic patients.

Research design and methods: In a six-month open-label parallel-group, multicenter study, adult patients (n = 180) with type 1 diabetes (>1 year), on a basal-bolus insulin regimen (>6 months), with HbA(1c) ≥ 8%, were randomized to usual quarterly follow-up (G1), home use of a smartphone recommending insulin doses with quarterly visits (G2), or use of the smartphone with short teleconsultations every 2 weeks but no visit until point end (G3).

Results: Six-month mean HbA(1c) in G3 (8.41 ± 1.04%) was lower than in G1 (9.10 ± 1.16%; P = 0.0019). G2 displayed intermediate results (8.63 ± 1.07%). The Diabeo system gave a 0.91% (0.60; 1.21) improvement in HbA(1c) over controls and a 0.67% (0.35; 0.99) reduction when used without teleconsultation. There was no difference in the frequency of hypoglycemic episodes or in medical time spent for hospital or telephone consultations. However, patients in G1 and G2 spent nearly 5 h more than G3 patients attending hospital visits.

Conclusions: The Diabeo system gives a substantial improvement to metabolic control in chronic, poorly controlled type 1 diabetic patients without requiring more medical time and at a lower overall cost for the patient than usual care.

Trial registration: ClinicalTrials.gov NCT00629304.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Trial profile.
Figure 2
Figure 2
Efficacy of electronic logbook ± teleconsultation. A: HbA1c values (means ± SE), from 3 months before baseline to month 6. *P = 0.0103, **P = 0.0019 compared with control group. B: Change in HbA1c values (means ± SE) from baseline to month 6.

References

    1. DAFNE Study Group Training in flexible, intensive insulin management to enable dietary freedom in people with type 1 diabetes: Dose Adjustment For Normal Eating (DAFNE) randomised controlled trial. BMJ 2002;325:746. - PMC - PubMed
    1. Bott S, Bott U, Berger M, Mühlhauser I. Intensified insulin therapy and the risk of severe hypoglycaemia. Diabetologia 1997;40:926–932 - PubMed
    1. Fagot-Campagna A, Fosse S, Roudier C, et al. Characteristics, vascular risk and complications in people with diabetes, in metropolitan France: major improvements between ENTRED 2001 and ENTRED 2007 studies. Bulletin Epidemiologique Hebdomadaire 2009;42–43:450–455[in French]
    1. American Diabetes Association Standards of medical care in diabetes—2010. Diabetes Care 2010;33(Suppl. 1):S11–S61 - PMC - PubMed
    1. Franc S, Dardari D, Boucherie B, et al. Real-life application and validation of flexible intensive insulin-therapy algorithms in type 1 diabetes patients. Diabetes Metab 2009;35:463–468 - PubMed

Publication types

Associated data