. 2011 May;32(10):1251-9.
doi: 10.1093/eurheartj/ehq518. Epub 2011 Jan 27.

In vivo critical fibrous cap thickness for rupture-prone coronary plaques assessed by optical coherence tomography

Affiliations

In vivo critical fibrous cap thickness for rupture-prone coronary plaques assessed by optical coherence tomography

Taishi Yonetsu et al. Eur Heart J. 2011 May.

Abstract

Aims: The widely accepted threshold of <65 μm for coronary plaque fibrous cap thickness was derived from postmortem studies of ruptured plaques and may not be appropriate for in vivo rupture-prone plaques. We investigated the relationship between fibrous cap thickness and plaque rupture using optical coherence tomography (OCT).

Methods and results: We studied 266 lesions (103 from patients with acute coronary syndrome and 163 from patients with stable angina) before percutaneous coronary intervention using OCT. Ruptured and non-ruptured lipid-rich plaques were identified and the thinnest and most representative fibrous cap thickness were determined. Cap thickness was reliably measured in 71 ruptured and 111 non-ruptured plaques. From the ruptured plaques, the median thinnest cap thickness was 54 μm (50-60). The median most representative cap thickness was 116 μm (103-136). For non-ruptured plaques, the median thinnest cap thickness was 80 μm (67-104) and 182 μm (156-216) for most representative cap thickness. In 95% of ruptured plaques, the thinnest cap thickness and most representative cap thickness were <80 and <188 μm, respectively. The best cut-offs for predicting rupture were <67 μm (OR: 16.1, CI: 7.5-34.4, P < 0.001) for the thinnest cap thickness and <151 μm (OR: 35.6, CI: 15.0-84.3, P < 0.001) for most representative cap thickness. These two measures were modestly correlated (r(2) = 0.39) and both independently associated with rupture.

Conclusion: In vivo critical cap thicknesses were <80 μm for the thinnest and <188 μm for most representative fibrous cap thickness. Prospective imaging studies are required to establish the significance of these values.