Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Apr;41(4):492-500.
doi: 10.1016/j.ejvs.2010.12.013. Epub 2011 Jan 26.

Patient-specific endovascular simulation influences interventionalists performing carotid artery stenting procedures

Affiliations
Free article

Patient-specific endovascular simulation influences interventionalists performing carotid artery stenting procedures

W I M Willaert et al. Eur J Vasc Endovasc Surg. 2011 Apr.
Free article

Abstract

Objective: The ability to perform patient-specific simulated rehearsal of complex endovascular interventions is a technological advance with potential benefits to patient outcomes. This study aimed to evaluate whether patient-specific rehearsal of a carotid artery stenting (CAS) procedure has an influence on tool selection and the use of fluoroscopy.

Methods: Following case note and computed tomography (CT) angiographic review of a real patient case, subjects performed the CAS procedure on a virtual reality simulator. Endovascular tool requirements and fluoroscopic angles were evaluated with a pre- and post-case questionnaire. Participants also rated the simulation from 1 (poor) to 5 (excellent).

Results: Thirty-three endovascular physicians with varying degrees of CAS experience were recruited: inexperienced (5-20 CAS procedures) n = 11, moderately (21-50 CAS procedures) n = 7 or highly experienced (>50 CAS procedures) n = 15. For all participants, 96 of a possible 363 changes (26%) were observed from pre- to post-case questionnaires. This was most notable for optimal fluoroscopy C-arm position 15/33 (46%), choice of selective catheter 13/33 (39%), choice of sheath or guiding catheter 11/33 (33%) and balloon dilatation strategy 10/33 (30%). Experience with the CAS procedure did not influence the degree of change significantly (p > 0.05), and all groups exhibited a considerable modification in tool and fluoroscopy preference. The model was considered realistic and useful as a tool to practice a real case (median score 4/5).

Conclusion: Patient-specific simulated rehearsal of a complex endovascular procedure strongly influences tool selection and fluoroscopy preferences for the real case. Further research has to evaluate how this technology may transfer from in vitro to in vivo and if it can reduce the radiation dose and the number of endovascular tools used and improve outcomes for patients in the clinical setting.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources