[Dot-ELISA using monoclonal antibody for detecting schistosome circulating antigen]
- PMID: 2129159
[Dot-ELISA using monoclonal antibody for detecting schistosome circulating antigen]
Abstract
Monoclonal antibodies were produced by the fusion of splenic lymphocytes from BALB/c mice immunized with Schistosoma japonicum excretory/secretory antigen and the myeloma cell line SP2/0. The 1B2E7B8 McAb was proved to be specific against the gut antigen of adult worm in IFA. The McAb labelled with HRP was used in Dot-ELISA to detect schistosome circulating antigen. Schistosome circulating antigen was detected in 152 out of 188 proven cases of schistosomiasis, accounting for a positive rate of 80.9%. The positive rates for circulating antigen in cases with 1-24, 25-99 and greater than or equal to 100 EPG were 76.8%, 86.6% and 100% respectively. 10 out of 11 cases who had been checked 2 months after effective treatment became ELISA negative. No circulating antigen was detected in cases with other parasitosis nor in normal individuals. In addition, the McAb-Dot-ELISA showed good reproducibility. The results indicated that McAb-Dot-ELISA might be used for diagnosis of schistosomiasis and evaluation of cure.
Similar articles
-
[Preparation and diagnostic application of monoclonal antibodies against Schistosoma japonicum].Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 1991;9(4):254-7. Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 1991. PMID: 1802447 Chinese.
-
[Detection of circulating membrane antigen of schistosome in schistosomiasis by dot-ELISA and idiotype/antiidiotype interaction inhibition test].Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 1991;9(4):265-8. Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 1991. PMID: 1802450 Chinese.
-
[Comparison of circulating antigen detection in schistosomiasis japonica patients using two methods of ELISA].Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 2000;18(4):227-8. Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 2000. PMID: 12567667 Chinese.
-
[Circulating antigen detection in schistosomiasis japonica patients by sandwich ELISA using polyclonal and monoclonal antibodies].Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 2000;18(2):92-3. Zhongguo Ji Sheng Chong Xue Yu Ji Sheng Chong Bing Za Zhi. 2000. PMID: 12567723 Chinese.
-
Immunodiagnosis of Schistosoma japonicum infection in China.Chin Med J (Engl). 1993 Aug;106(8):623-7. Chin Med J (Engl). 1993. PMID: 8222913 Review.