Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction
- PMID: 21321152
- DOI: 10.1161/CIRCULATIONAHA.110.983510
Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction
Erratum in
- Circulation. 2011 Sep 20;124(12):e336
Abstract
Background: Retrospective studies have suggested that patients with a low transvalvular gradient in the presence of an aortic valve area < 1.0 cm² and normal ejection fraction may represent a subgroup with an advanced stage of aortic valve disease, reduced stroke volume, and poor prognosis requiring early surgery. We therefore evaluated the outcome of patients with low-gradient "severe" stenosis (defined as aortic valve area < 1.0 cm² and mean gradient ≤ 40 mm Hg) in the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study.
Methods and results: Outcome in patients with low-gradient "severe" aortic stenosis was compared with outcome in patients with moderate stenosis (aortic valve area 1.0 to 1.5 cm²; mean gradient 25 to 40 mm Hg). The primary end point of aortic valve events included death from cardiovascular causes, aortic valve replacement, and heart failure due to aortic stenosis. Secondary end points were major cardiovascular events and cardiovascular death. In 1525 asymptomatic patients (mean age, 67 ± 10 years; ejection fraction, ≥ 55%), baseline echocardiography revealed low-gradient severe stenosis in 435 patients (29%) and moderate stenosis in 184 (12%). Left ventricular mass was lower in patients with low-gradient severe stenosis than in those with moderate stenosis (182 ± 64 versus 212 ± 68 g; P < 0.01). During 46 months of follow-up, aortic valve events occurred in 48.5% versus 44.6%, respectively (P = 0.37; major cardiovascular events, 50.9% versus 48.5%, P = 0.58; cardiovascular death, 7.8% versus 4.9%, P = 0.19). Low-gradient severe stenosis patients with reduced stroke volume index (≤ 35 mL/m²; n = 223) had aortic valve events comparable to those in patients with normal stroke volume index (46.2% versus 50.9%; P = 0.53).
Conclusions: Patients with low-gradient "severe" aortic stenosis and normal ejection fraction have an outcome similar to that in patients with moderate stenosis.
Comment in
-
Low-gradient "severe" aortic stenosis with normal systolic function: time to refine the guidelines?Circulation. 2011 Mar 1;123(8):838-40. doi: 10.1161/CIRCULATIONAHA.110.015826. Epub 2011 Feb 14. Circulation. 2011. PMID: 21321159 No abstract available.
-
Letter by Dumesnil and Pibarot regarding article, "Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction".Circulation. 2011 Sep 27;124(13):e360; author reply e362-3. doi: 10.1161/CIRCULATIONAHA.111.038497. Circulation. 2011. PMID: 21947940 No abstract available.
-
Letter by Daneshvar regarding article, "Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction".Circulation. 2011 Sep 27;124(13):e361; author reply e362-3. doi: 10.1161/CIRCULATIONAHA.111.041012. Circulation. 2011. PMID: 21947941 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources