Catheter-related bloodstream infections
- PMID: 21326505
- PMCID: PMC3036424
- DOI: 10.1055/s-0029-1222458
Catheter-related bloodstream infections
Abstract
Tunneled, cuffed, double-lumen catheters are commonly used for long-term venous access in hemodialysis patients. Complications of these catheters, including catheter-related infection, are a major cause of morbidity and resource utilization in the hemodialysis population. Treatment of catheter-related bloodstream infections includes the use of antibiotics and evaluation of the need for catheter removal or exchange. Measures to prevent catheter-related infections include use of an aseptic technique and antiseptic cleaning solution, elimination of Staphylococcus aureus nasal carriage, topical exit site application of antibiotics, use of antibiotic lock solutions, and use of catheters and cuffs coated or impregnated with antimicrobial or antiseptic agents. This review article will provide an update on the prevalence, diagnosis, treatment, and prevention of catheter-related infections in the hemodialysis population.
Keywords: Hemodialysis catheters; antibiotic prophylaxis; catheter-related infection.
References
-
- National Kidney Foundation KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis adequacy, peritoneal dialysis adequacy and vascular access. Am J Kidney Dis. 2006;48(Suppl 1):S1–S322. - PubMed
-
- Tokars J I, Miller E R, Alter M J, Arduino M J. National surveillance of dialysis-associated diseases in the United States, 1997. Semin Dial. 2000;13(2):75–85. - PubMed
-
- Mermel L, Farr B, Sheretz R J, et al. Guidelines for the management of intravascular catheter related infections—Executive Summary. Clin Infect Dis. 2001;32:1249–1272. - PubMed
-
- Taylor G, Gravel D, Johnston L, Embil J, Holton D, Paton S, Canadian Nosocomial Infection Surveillance Program. Canadian Hospital Epidemiology Committee Incidence of bloodstream infection in multicenter inception cohorts of hemodialysis patients. Am J Infect Control. 2004;32(3):155–160. - PubMed
-
- Saad T F. Bacteremia associated with tunneled, cuffed hemodialysis catheters. Am J Kidney Dis. 1999;34(6):1114–1124. - PubMed