Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2011 Mar;75(3):212-7.
doi: 10.5414/cn106460.

The effect of heparinized catheter lock solutions on systemic anticoagulation in hemodialysis patients

Affiliations
Randomized Controlled Trial

The effect of heparinized catheter lock solutions on systemic anticoagulation in hemodialysis patients

P C Thomson et al. Clin Nephrol. 2011 Mar.

Abstract

Background: Hemodialysis catheter thrombosis is associated with loss of catheter patency, catheter-related bacteremia and sepsis. To limit these risks, many renal units use heparin as a catheter-locking solution. In this study we investigate the effect of different concentrations of heparin catheter lock solution on systemic anticoagulation in an investigator-blinded randomized study of patients with non-tunneled (temporary) central venous catheters.

Methods: 28 consecutive patients requiring insertion of a temporary non-tunneled dual lumen central venous hemodialysis catheter were randomly allocated to receive either heparin 5,000 IU/ml or heparin 1,000 IU/ml as catheter lock solutions. The primary outcome measure was the difference in activated partial thromboplastin time (APTT) at 10 minutes following catheter locking with heparin 5,000 IU/ml and heparin 1,000 IU/ml. Secondary outcomes included intradialytic blood flow rates, catheter removal due to insufficient hemodialysis blood flow to maintain hemodialysis and catheter-related bacteremia.

Results: 13 patients were randomized to the heparin 1,000 IU/ml group with 15 patients randomized to the heparin 5,000 IU/ml group. There was a statistically significant increase in APTT at 10 minutes between groups with median +22.2% (range 0 - 210) rise in APTT in the heparin 1,000 IU/ml group compared with +373.7% (range 133 - 800) in the heparin 5,000 IU/ml group (p < 0.001). There was no statistically significant difference between groups with the secondary outcomes of intradialytic blood flow, catheter failure rates and catheter-related bacteremia rates.

Conclusions: Heparin 1,000 IU/ml catheter lock solution confers a significantly lower risk of systemic heparinization than heparin 5,000 IU/ml without any overtly detrimental effect on intradialytic blood flow, catheter failure rates and catheter-related bacteremia rates.