High spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance using k-t SENSE
- PMID: 21345497
- DOI: 10.1016/j.ijcard.2011.01.060
High spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance using k-t SENSE
Abstract
Purpose: To prospectively evaluate the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance (DSMR) for the detection of coronary artery disease (CAD).
Methods and results: DSMR-wall motion was combined with perfusion imaging (DSMR-perfusion) in 78 patients prior to clinically indicated invasive coronary angiography. For DSMR-perfusion an in-plane spatial resolution of 1.5 × 1.5mm(2) was attained by using 8 × k-space and time sensitivity encoding (k-t SENSE). Image quality and extent of artifacts during perfusion imaging were evaluated. Wall motion and perfusion data were interpreted sequentially. Significant CAD (stenosis ≥ 70%) was present in 52 patients and involved 86 coronary territories. One patient did not reach target heart rate despite maximum infusion of dobutamine/atropine. Two studies (3%) were non-diagnostic due k-t SENSE related artifacts resulting from insufficient breathhold capability. Overall image quality was good. Dark-rim artifacts were limited to the endocardial border at a mean width of 1.8mm. The addition of DSMR-perfusion to DSMR-wall motion data improved sensitivity for the detection of CAD (92% vs. 81%, P=0.03) and accurate determination of disease extent (85% vs. 66% of territories, P<0.001). There were no significant differences between DSMR-perfusion and DSRM-wall motion regarding overall specificity (83% vs. 87%, P=1) and accuracy (89% vs. 83%, P=0.13).
Conclusion: High spatial resolution DSMR-perfusion imaging at maximum stress level was feasible, improved sensitivity over DSMR-wall motion for the detection of CAD and allowed an accurate determination of disease extent. Specificity of DSMR-perfusion with k-t SENSE improved compared to prior studies using lower spatial resolution.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
Value of additional myocardial perfusion imaging during dobutamine stress magnetic resonance for the assessment of intermediate coronary artery disease.Int J Cardiovasc Imaging. 2012 Jan;28(1):89-97. doi: 10.1007/s10554-010-9764-3. Epub 2010 Dec 14. Int J Cardiovasc Imaging. 2012. PMID: 21153708
-
Additional value of myocardial perfusion imaging during dobutamine stress magnetic resonance for the assessment of coronary artery disease.Circ Cardiovasc Imaging. 2008 Sep;1(2):122-30. doi: 10.1161/CIRCIMAGING.108.779108. Epub 2008 Jul 30. Circ Cardiovasc Imaging. 2008. PMID: 19808529
-
High-dose dobutamine-atropine stress cardiovascular MR imaging after coronary revascularization in patients with wall motion abnormalities at rest.Radiology. 2004 Oct;233(1):210-6. doi: 10.1148/radiol.2331030463. Epub 2004 Aug 10. Radiology. 2004. PMID: 15304662
-
[Stress cine MRI for detection of coronary artery disease].Rofo. 2002 May;174(5):605-13. doi: 10.1055/s-2002-28277. Rofo. 2002. PMID: 11997861 Review. German.
-
Cardiac stress MR imaging with dobutamine.Eur Radiol. 2006 Dec;16(12):2728-38. doi: 10.1007/s00330-006-0295-1. Epub 2006 May 20. Eur Radiol. 2006. PMID: 16715237 Review.
Cited by
-
Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis.Eur Radiol. 2012 Sep;22(9):1881-95. doi: 10.1007/s00330-012-2434-1. Epub 2012 Apr 19. Eur Radiol. 2012. PMID: 22527375 Free PMC article.
-
Three-dimensional contrast-enhanced and non-contrast-enhanced cardiac magnetic resonance imaging for the assessment of myocardial ischemic reactions: the practice of looking deeply into the myocardium.J Nucl Cardiol. 2011 Oct;18(5):937-51. doi: 10.1007/s12350-011-9391-y. J Nucl Cardiol. 2011. PMID: 21567282 Review. No abstract available.
-
Free-breathing cardiac MR stress perfusion with real-time slice tracking.Magn Reson Med. 2014 Sep;72(3):689-98. doi: 10.1002/mrm.24977. Epub 2013 Oct 7. Magn Reson Med. 2014. PMID: 24123153 Free PMC article. Clinical Trial.
-
Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.Magn Reson Med. 2014 Jul;72(1):124-36. doi: 10.1002/mrm.24913. Epub 2013 Sep 12. Magn Reson Med. 2014. PMID: 24030840 Free PMC article.
-
MRI reconstruction of multi-image acquisitions using a rank regularizer with data reordering.Med Phys. 2015 Aug;42(8):4734-44. doi: 10.1118/1.4926777. Med Phys. 2015. PMID: 26233201 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous