Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2012 Jul 26;158(3):411-6.
doi: 10.1016/j.ijcard.2011.01.060. Epub 2011 Feb 23.

High spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance using k-t SENSE

Affiliations
Clinical Trial

High spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance using k-t SENSE

R Gebker et al. Int J Cardiol. .

Abstract

Purpose: To prospectively evaluate the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance (DSMR) for the detection of coronary artery disease (CAD).

Methods and results: DSMR-wall motion was combined with perfusion imaging (DSMR-perfusion) in 78 patients prior to clinically indicated invasive coronary angiography. For DSMR-perfusion an in-plane spatial resolution of 1.5 × 1.5mm(2) was attained by using 8 × k-space and time sensitivity encoding (k-t SENSE). Image quality and extent of artifacts during perfusion imaging were evaluated. Wall motion and perfusion data were interpreted sequentially. Significant CAD (stenosis ≥ 70%) was present in 52 patients and involved 86 coronary territories. One patient did not reach target heart rate despite maximum infusion of dobutamine/atropine. Two studies (3%) were non-diagnostic due k-t SENSE related artifacts resulting from insufficient breathhold capability. Overall image quality was good. Dark-rim artifacts were limited to the endocardial border at a mean width of 1.8mm. The addition of DSMR-perfusion to DSMR-wall motion data improved sensitivity for the detection of CAD (92% vs. 81%, P=0.03) and accurate determination of disease extent (85% vs. 66% of territories, P<0.001). There were no significant differences between DSMR-perfusion and DSRM-wall motion regarding overall specificity (83% vs. 87%, P=1) and accuracy (89% vs. 83%, P=0.13).

Conclusion: High spatial resolution DSMR-perfusion imaging at maximum stress level was feasible, improved sensitivity over DSMR-wall motion for the detection of CAD and allowed an accurate determination of disease extent. Specificity of DSMR-perfusion with k-t SENSE improved compared to prior studies using lower spatial resolution.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources