. 1990 Jul-Sep;85(3):339-45.
doi: 10.1590/s0074-02761990000300011.

The thermal stability of yellow fever vaccines

Affiliations
Free article

The thermal stability of yellow fever vaccines

R Ishak et al. Mem Inst Oswaldo Cruz. 1990 Jul-Sep.
Free article

Abstract

The assessment of yellow fever vaccine thermostability both in lyophilized form and after reconstitution were analyzed. Two commercial yellow fever vaccines were assayed for their thermal stability. Vaccines were exposed to test temperatures in the range of 8 degrees C to 45 degrees C. Residual infectivity was measured by a plaque assay using Vero cells. The titre values were used in an accelerated degradation test that follows the Arrhenius equation and the minimum immunizing dose was assumed to be 10(3) particles forming unit (pfu)/dose. Some of the most relevant results include that (i) regular culture medium show the same degradation pattern of a reconstituted 17D-204 vaccine; (ii) reconstituted YF-17D-204 showed a predictable half life of more than six days if kept at 0 degrees C; (iii) there are differences in thermostability between different products that are probably due to both presence of stabilizers in the preparation and the modernization in the vaccine production; (iv) it is important to establish a proper correlation between the mouse infectivity test and the plaque assay since the last appears to be more simple, economical, and practical for small laboratories to assess the potency of the vaccine, and (v) the accelerated degradation test appears to be the best procedure to quantify the thermostability of biological products.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources