Randomized Controlled Trial
. 2011 Jun;31(6):1109-17.
doi: 10.1097/IAE.0b013e31820b5b9b.

Study of intraocular pressure after 23-gauge and 25-gauge pars plana vitrectomy randomized to fluid versus air fill

Affiliations
Randomized Controlled Trial

Study of intraocular pressure after 23-gauge and 25-gauge pars plana vitrectomy randomized to fluid versus air fill

Lawrence Y Ho et al. Retina. 2011 Jun.

Abstract

Purpose: To determine if a difference in intraocular pressure (IOP) exists after small-gauge pars plana vitrectomy randomized to fluid versus 80% sterile air fill.

Methods: Ninety-two eyes undergoing 23-gauge and 25-gauge transconjunctival pars plana vitrectomy were randomized to fluid versus air fill, and IOP was measured at 5 different time points.

Results: There is no difference in the mean IOP for eyes undergoing small-gauge pars plana vitrectomy randomized to fluid versus air fill after vitrectomy. Using 23-gauge instrumentation, the mean immediate and 2-hour postoperative IOPs were statistically lower than the mean preoperative IOP. The mean Postoperative Day 1 and Week 1 IOPs were statistically higher than the mean immediate postoperative IOP. Using 25-gauge instrumentation, the mean IOP was not statistically different at any time points in the 2 groups. When comparing 23-gauge with 25-gauge instrumentation, the immediate postoperative IOP was statistically lower and the rate of suture closure for sclerotomies was higher for 23-gauge vitrectomy.

Conclusion: When performing 23-gauge or 25-gauge pars plana vitrectomy, there was no difference in mean IOP for fluid- versus air-filled eyes. However, the mean IOP in the immediate postoperative period was statistically lower, and there was a higher rate of suture closure for 23-gauge compared with 25-gauge instrumentation.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources