Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Apr;400(2):587-94.
doi: 10.1007/s00216-011-4781-1. Epub 2011 Feb 26.

Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents

Affiliations

Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents

Michael G Cahill et al. Anal Bioanal Chem. 2011 Apr.

Abstract

Effluent from wastewater treatment plants have been identified as an important source of micro-organic contaminants in the environment. An online high-performance liquid chromatography-heated electrospray ionization tandem mass spectrometric method was developed and validated for the determination of basic pesticides in effluent wastewaters. Most available methods for pesticide analysis of wastewater samples are time-consuming, require complex clean-up steps and are difficult to automate. The method developed used a simple solid-phase extraction clean-up for salt and lipid reduction. On-line sample pre-concentration was performed using a reversed phase (C(18)) column, and analytes were separated by back-flushing onto an analytical column (C(8)) with detection using QqQ MS. An option to increase MS resolution was exploited to minimize interference from endogenous compounds in the matrix. A better than unit mass resolution was used (Q1 full width half maximum (FWHM) = 0.2 Da and Q3 FWHM = 0.7 Da), which was as rugged as a unit resolution method, and improved signal/noise and better detection limits were achieved for the targeted basic pesticides. This method was applied to the determination of 11 pesticides, including methoxytriazine, chlorotriazines, chloroacetanilides, phenylurea and carbamate pesticides. The percentage recovery values for these pesticides using the online trapping column were within the range, 73-95%, with relative standard deviation (RSD) values <8.9%. The highest concentrations of these pesticides in wastewater effluents in County Cork, Ireland, were simazine (0.51 μg/L), prometon (0.14 μg/L), diuron (0.21 μg/L) and atrazine (0.19 μg/L).

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources